4. Troubleshooting
Code 5273: “dmd blue fan - speed low” (Warning)
Situation
Solution
Wire unit of the fan disconnected.
Check if the wire unit of the fan is connected with the Signal backplane See reference
3 image 4-23.
Check the fan connection with the wire unit to the signal backplane.
Blocked fan.
Unblock the fan. Ensure that the fan can turn freely.
Damaged wire unit.
Check if the wire unit of the fan is not damaged. Repair if possible, otherwise replace
with new one.
Fan end of life.
Replace the fan.
Malfunction Fan & Motor Control
Board
Replace the Fan & Motor Control Board. See "Removing a board in the card cage",
page 213.
Other fans are also not spinning.
Replace the SMPS Board. See "Replacement of the Switched Mode Power Supply",
page 281.
Defect Signal Backplane
Replace the Signal Backplane, see "Replacement of the signal back plane", page 231.
Code 5280: “ambient - temperature too high” (Error)
This error code is probably preceded by the warning code: ambient - temperature high”.
Situation
Solution
Ambient temperature too high.
Check the ambient temperature at the air inlets of the projector. Make sure that the
ambient temperature does not exceed 35°C (95°F).
Blocked
fi
lter at the front side of the
projector.
Clean the front
fi
lter or replace with new one. See "Removing the front dust
Malfunction air extraction system.
Check the condition of the air extraction system. The air extraction system must be
capable of removing minimum 6,65 m³/min or 235 CFM per installed digital projector.
Malfunction Fan Control board.
Replace the Fan Control board. See "Removing a board in the card cage", page 213.
Code 5281: “ambient - temperature high” (Warning)
Situation
Solution
Blocked high density
fi
lter at the front
side of the projector.
Replace the front high density
fi
lter with a new one. See "Removing the front dust
Ambient temperature too high.
Check the ambient temperature at the air inlets of the projector. Make sure that the
ambient temperature does not exceed 35°C (95°F).
Malfunction air extraction system.
Check the condition of the air extraction system. The air extraction system must be
capable of removing minimum 6,65 m³/min or 235 CFM per installed digital projector.
Code 5283: “ambient - temperature low” (Warning)
Situation
Solution
Ambient temperature is too low.
Check the ambient temperature at the air inlets of the projector. Makes sure that the
ambient temperature is not lower than 0°C (32°F).
Defect temperature sensor.
Replace the Fan & Motor Control board. See "Removing a board in the card cage",
page 213.
Malfunction Fan & Motor Control
board.
Replace the Fan & Motor Control board. See "Removing a board in the card cage",
page 213.
Code 5284: “ambient - temperature sensor open” (Error)
Situation
Solution
Malfunction Fan Control board.
Replace the Fan Control board, see "Removing a board in the card cage", page 213.
Code 5285: “ambient - temperature sensor short” (Error)
Situation
Solution
Malfunction Fan Control board.
Replace the Fan Control board. See "Removing a board in the card cage", page 213.
R5905043 DP2K-12C/11CX 19/02/2018
43
Summary of Contents for DP2K-12C
Page 1: ...DP2K 12C 11CX Service manual R5905043 15 19 02 2018...
Page 4: ......
Page 8: ...Table of contents 4 R5905043 DP2K 12C 11CX 19 02 2018...
Page 12: ...1 Safety 8 R5905043 DP2K 12C 11CX 19 02 2018...
Page 31: ...4 Troubleshooting 4 TROUBLESHOOTING R5905043 DP2K 12C 11CX 19 02 2018 27...
Page 32: ...4 Troubleshooting 28 R5905043 DP2K 12C 11CX 19 02 2018...
Page 96: ...5 Removal and installation of projector covers 92 R5905043 DP2K 12C 11CX 19 02 2018...
Page 121: ...6 Lamps and lamp houses Image 6 38 R5905043 DP2K 12C 11CX 19 02 2018 117...
Page 138: ...7 Cold mirror assembly 134 R5905043 DP2K 12C 11CX 19 02 2018...
Page 222: ...12 Card Cage 1 Image 12 11 218 R5905043 DP2K 12C 11CX 19 02 2018...
Page 225: ...12 Card Cage Image 12 15 Button unit removal R5905043 DP2K 12C 11CX 19 02 2018 221...
Page 281: ...15 Power input Image 15 13 Mains AC compartment cover R5905043 DP2K 12C 11CX 19 02 2018 277...
Page 282: ...15 Power input 278 R5905043 DP2K 12C 11CX 19 02 2018...
Page 306: ...18 Lamp power supply single module 302 R5905043 DP2K 12C 11CX 19 02 2018...
Page 340: ...21 Maintenance procedures 336 R5905043 DP2K 12C 11CX 19 02 2018...
Page 350: ...A Pin configurations 346 R5905043 DP2K 12C 11CX 19 02 2018...
Page 351: ...B Input formats B INPUT FORMATS R5905043 DP2K 12C 11CX 19 02 2018 347...
Page 352: ...B Input formats 348 R5905043 DP2K 12C 11CX 19 02 2018...