GEOMETRY (continued)
HFR HORIZONTAL FREQUENCY UP & DOWN
Horizontal frequency adjustment.
PHA HORIZONTAL PHASE UP & DOWN
Horizontal phase adjustment. UP means to the right.
PW
PICTURE WIDTH UP & DOWN
Picture width or horizontal amplitude adjustment.
EWP
EAST-WEST PARABOLA UP & DOWN
East-West correction setting.
EWC
EAST-WEST CORNER UP & DOWN
East-West corner adjustment.
LIN
VERTICAL LINEARITY UP & DOWN
Vertical linearity adjustment.
SHF
VERTICAL SHIFT UP & DOWN
Vertical picture position setting.
PH
PICTURE HEIGHT UP & DOWN
Picture height or vertical amplitude adjustment.
VSC VERTICAL S-CORRECTION UP & DOWN
Vertical S-correction setting.
SYNC Key to interrupt synchronization of the internal line
oscillator during alignment of the horizontal free-running
frequency using the HFR UP & DOWN keys. The SYNC
LED is
lit when synchronizaton is interrupted.
EXIT
Key to leave the geometry adjustment mode without
saving.
PRINT A single key press starts the transmission of a report of
geometry control values to a printer (if connected) via the
REMOTE 1 connector on the rear.
SAVE
Key to leave the geometry adjustment mode with saving.
To do so, press this key once so that the the green KEY
LED
lights up one time.
HELP ON/OFF Key to switch on/off the on-screen help text.
UNDERSCAN Key to select underscan size.
Underscan is identified by means of an enlighted green
LED
above this key.
OVERSCAN Key to select overscan size.
Overscan is identified by means of an enlighted green LEo
above this key.
4/3-16/9 (*) Key to toggle between 4/3 and 16/9. The led in this
key is lit when 16/9 is selected. The (*) marks the se-
lected state when the LED is on.
COPY UNDERSCAN Key to copy the geometry values set for
underscan size to overscan. It does not matter to what
scan size the monitor is set at that moment.
COPY TO 16/9 Key to copy the geometry values of 413 to 16/9.
35