RIS CONFIGURATION
Mode selection : INPUT SWITCHING ONLY
To specify inputs in input switching mode : 0
To return without saving :
To return with saving
CLEAR
ENTER
INP 1
INP 2
INP 3
INP 4
INPUT SWITCHING MODE
SW 1
SW2
open
closed
open
open
closed
open
closed
closed
SELECTED INPUT
To return without saving :
To return with saving
CLEAR
ENTER
MONITOR CONFIGURATION
(continued)
The RIS Configuration Menu looks like this :
Two modes are available : "INPUT
SWITCHING ONLY"
and
"FUNCTION SWITCHING"
. The red field in the menu shows the
actual mode. Press TOGL to modify it.
Press 0 to get a menu for determination of the function of the two
switches SW1 and SW2. In such a menu :
Press
UP
or
DOWN
to move the red field.
Press
TOGL
to modify data in the red field.
Press
CLEAR
to return without saving.
Press
ENTER
to return with saving.
For "INPUT
SWITCHING ONLY",
you get e.g. next menu (setting
most compatible with all other BARCO monitors) :
In case of an analog Component Module, 4 inputs can be set. If a
Digital Module, 4 out of 6 inputs can be defined.
The front panel and the remote control are active at the same time.
A remote input selection is carried out from the instant the status of
one of the two switches SW1 and SW2 is modified.
continued on next page
20