Flue gas mass flow
9.5 g/s
Flue gas temperature
274 °C
Chimney draught
12 Pa (0,12 mbar)
Flue gas connection
Ø 207 mm, suitable for a pipe with an outer di-
ameter of 200 mm
W
Weight
• Basic appliance
• Áppliance with adjustable height frames and
convection ventilator
• 193 kg
• 221 kg
Minimum insulation thickness to combustible
walls
• side wall
• back wall
• floor
• ceiling
• 100 mm
• 100 mm
• 100 mm
• 40 mm
I' index
0.4
Used materials
• Combustion chamber side panels
Cast iron
• Combustion chamber insulation
Vermiculite 750 kg/m
3
• Combustion floor and grate
Steel
• Lower baffle
Heat resistant ceramic 2000 kg/m
3
• Upper baffle
Vermiculite 750 kg/m
3
Combustion air supply
Pipe connection with diameter of 125 mm on the
appliance or 3 holes with diameter of 125 mm
on the optional convection ventilator / combus-
tion air inlet box
Options
• Convection ventilator / combustion air inlet
box
• Combustion air inlet box
• Set of 2 adjustable height frames
Electrical energy consumption:
• Convection ventilator
69 W; 230 VAC
The specific precautions that shall be taken
when the local space heater is assembled, in-
stalled or maintained, are listed in the attached
documents:
• Installation and maintenance manual
• User manual
Technical data
30
Falcon 59/70
Summary of Contents for Falcon 59/70
Page 1: ...I Installation and maintenance manual Falcon 59 70 Serial number Production date...
Page 27: ...Annual maintenance Falcon 59 70 2 27...
Page 31: ...8 8 Dimensions 8 1 Frameless appliance Dimensions Falcon 59 70 31...
Page 33: ...8 8 3 Appliance with 3 sided classic frame Dimensions Falcon 59 70 33...
Page 34: ...8 8 4 Appliance with 4 sided classic frame Dimensions 34 Falcon 59 70...
Page 37: ...Warranty Terms Falcon 59 70 3 37...
Page 38: ...Warranty Terms 3 38 Falcon 59 70...