Declaration of performance
1.
Unique identification code of the product-type
2.
Intended use or uses of the construction product, in
accordance with the applicable harmonised technical
specification, as foreseen by the manufacturer
3.
Name, registered trade name or registered trade mark
and contact address of the manufacturer as required
pursuant to Article 11(5)
4.
Where applicable, name and contact address of the
authorised representative whose mandate covers the
tasks specified in Article 12(2)
5.
System or systems of assessment and verification of
constancy of performance of the construction product
as set out in Annex V
6.
In case of the declaration of performance concerning a
construction product covered by a harmonised
standard
7.
Declared performance
Fire safety
Minimum distances, in mm
Insulation thickness rear =
100
Insulation thickness sides =
100
Insulation thickness ceiling =
40
Front =
1000
Insulation thickness floor =
100
NPD
Thermal output
Energy efficiency
8.
Signed for and on behalf of the manufacturer by:
Danny Baijens, CEO
(Name and function)
Bladel; June 8, 2018
………………………………………………………………………
(place and date of issue)
(Signature)
PM = 19 mg/m3
NOx = 88 mg/m3
OGC = 57 mg/m3
Release of dangerous substances
Pass
Emission of combustion products
Mechanical resistance (to carry a chimney/flue)
Surface temperature
Risk of burning fuel falling out
Pass
Declaration of Performance
According to regulation (EU) 305/2011
No. 3.128.003-0 - CPR-2013/07/01
Barbas Falcon 59/70 - 3.128.003-0 Room heater without hot water supply
EN13229:2001/A2:2004/AC:2007
Room heater without hot water supply
Barbas Bellfires BV; Hallenstraat 17; 5531 AB Bladel; The Netherlands
Not applicable
System 3
The notified laboratory SGS Nederland BV, No. 0608 performed the
determination of the product type on the basis of type testing under system 3
and issued test report EZKA/2018-01/00004-9
Harmonized technical specification
EN13229:2001/A2:2004/AC:2007
Essential characteristics
Performance
Reaction to fire
A1
Distance to combustible materials
CO = 941 mg/m3
Pass
Pass
Nominal heat output
9.9 kW
Room heating output
9.9 kW
Electrical safety
Pass
Cleanability
Pass
Maximum operating pressure
Not applicable
Flue gas temperature at nominal heat output
T = 274 °C
78.5 %
NPD
The performance of the product identified in point 1 is in conformity with the declared performance in point 7.
This declaration of performance is issued under the sole responsibility of the manufacturer identified in point 3.
Water heating output
- kW
Durability
Pass
Declaration of performance
Falcon 59/70
5
Summary of Contents for Falcon 59/70
Page 1: ...I Installation and maintenance manual Falcon 59 70 Serial number Production date...
Page 27: ...Annual maintenance Falcon 59 70 2 27...
Page 31: ...8 8 Dimensions 8 1 Frameless appliance Dimensions Falcon 59 70 31...
Page 33: ...8 8 3 Appliance with 3 sided classic frame Dimensions Falcon 59 70 33...
Page 34: ...8 8 4 Appliance with 4 sided classic frame Dimensions 34 Falcon 59 70...
Page 37: ...Warranty Terms Falcon 59 70 3 37...
Page 38: ...Warranty Terms 3 38 Falcon 59 70...