• Combustion chamber insulation
Vermiculite 750 kg/m
3
• Combustion floor and grate
Steel
• Lower baffle
Heat resistant ceramic 2000 kg/m
3
• Upper baffle
Vermiculite 750 kg/m
3
Combustion air supply
Pipe connection with diameter of 125 mm on the
appliance or 3 holes with diameter of 125 mm
on the optional convection ventilator / combus-
tion air inlet box
O
Options
• Convection ventilator / combustion air inlet
box
• Combustion air inlet box
• Set of 2 adjustable height frames
Electrical energy consumption:
• Convection ventilator
69 W; 230 VAC
The specific precautions that shall be taken
when the local space heater is assembled, in-
stalled or maintained, are listed in the attached
documents:
• Installation and maintenance manual
• User manual
7.2
Technical data
Table 9: Technical data Falcon 59/70
Name
Barbas
Model
Falcon 59/70
Tested in accordance with
EN 13229:2001-A2:2004
EN16510-1 annex D, E, F
Energy efficiency index
104.5
Energy efficiency class
A
Fuel
Wood logs, Wood briquettes
Nominal fuel load
2.1 kg
Nominal heat output (net)
9.9 kW
Minimum heat output (net)
7 kW
Useful efficiency at nominal heat output
78.5 %
Useful efficiency at minimum heat output (indi-
cative)
82 %
Indirect heating function
No
Leak rate at 10 Pa
0.9 m
3
/h (at 273 K, 1013 hPa)
Emissions (at 13 % O
2
, 273 K, 1013 hPa)
• carbon monoxide (CO)
0.08 vol% (941 mg/Nm
3
)
• particles (PM)
19 mg/Nm
3
• organic gaseous compounds (OGC)
57 mg/Nm
3
• nitrogen oxides (NO
x
)
88 mg/Nm
3
Technical data
Falcon 59/70
29
Summary of Contents for Falcon 59/70
Page 1: ...I Installation and maintenance manual Falcon 59 70 Serial number Production date...
Page 27: ...Annual maintenance Falcon 59 70 2 27...
Page 31: ...8 8 Dimensions 8 1 Frameless appliance Dimensions Falcon 59 70 31...
Page 33: ...8 8 3 Appliance with 3 sided classic frame Dimensions Falcon 59 70 33...
Page 34: ...8 8 4 Appliance with 4 sided classic frame Dimensions 34 Falcon 59 70...
Page 37: ...Warranty Terms Falcon 59 70 3 37...
Page 38: ...Warranty Terms 3 38 Falcon 59 70...