• The fireplace must have ventilation openings near the bottom and near the top of the
fireplace.
• The total ventilation air inlet openings must have an area of at least 450 cm
2
. (For
example 2 inlet openings with an area of at least 225 cm
2
each.)
• The total ventilation air outlet openings must have an area of at least 450 cm
2
. (For
example 2 outlet openings with an area of at least 225 cm
2
each.)
55.1.3
Requirements on the chimney
• Make sure that in case of use of an existing (masonry) chimney, it is in good order and
applicable for the appliance. Ask your dealer or chimney sweeper for advice.
• Make sure the flue system obeys the national and local applicable regulations.
• Do not connect more than one appliance to the same chimney.
• The flue system must have a temperature class designation of at least T400.
• The inner diameter of the existing chimney must be at least 200 mm.
• Do not use more than 2 bends of 45°.
• The chimney outlet must be at least 5 meter above the top of the appliance.
• The chimney outlet must be at least 40 cm above the top of a sloped roof.
• The chimney outlet must be at least 1 meter above a flat roof.
• The chimney outlet must be free from any objects (buildings, trees, etc.) within a
horizontal range of at least 5 meter.
• Make sure your fire insurance policy covers any damage caused by a chimney fire.
5.2
Preparation for installation
• If applicable, make sure a 230 VAC grounded electrical connection is located near the
installation location.
Warning:
• The electrical connection must be grounded.
• The electrical connection must be made by a certified electrician.
• Make sure the electrical connection can always be accessed.
• Make sure the door of the appliance opens and closes correctly.
• Make sure the baffle is in the correct position
• Make sure the control lever can move freely to left and to right.
• Make sure the ashtray is empty.
Installation
16
Falcon 59/70
Summary of Contents for Falcon 59/70
Page 1: ...I Installation and maintenance manual Falcon 59 70 Serial number Production date...
Page 27: ...Annual maintenance Falcon 59 70 2 27...
Page 31: ...8 8 Dimensions 8 1 Frameless appliance Dimensions Falcon 59 70 31...
Page 33: ...8 8 3 Appliance with 3 sided classic frame Dimensions Falcon 59 70 33...
Page 34: ...8 8 4 Appliance with 4 sided classic frame Dimensions 34 Falcon 59 70...
Page 37: ...Warranty Terms Falcon 59 70 3 37...
Page 38: ...Warranty Terms 3 38 Falcon 59 70...