Figure 42. Position of primary air inlets and gas injectors
Table 12: Dimensions of primary air inlet / gas injectors
No.
Natural gas
G20
Butane G30
Propane G31
Biopropane G31
Primary air inlet first main burner
A
Ø5.0 mm
1x Ø8x15 mm + 2x Ø3.5 mm
B
Ø4.0 mm
1x Ø8x15 mm + 2x Ø3.5 mm
C
Ø5.0 mm
1x Ø8x15 mm + 2x Ø3.5 mm
Primary air inlet second main
burner
D
Ø4.0 mm
1x Ø8x15 mm + 2x Ø3.5 mm
E
Ø4.0 mm
1x Ø8x15 mm + 2x Ø3.5 mm
F
Ø4.0 mm
1x Ø8x15 mm + 2x Ø3.5 mm
G
Ø4.0 mm
1x Ø8x15 mm + 2x Ø3.5 mm
First main burner gas injector
A
Ø1.50 mm
Ø0.75 mm
B
Ø1.30 mm
Ø0.65 mm
C
Ø1.50 mm
Ø0.75mm
Second main burner gas injector
D
Ø0.95 mm
Ø0.60 mm
E
Ø1.20 mm
Ø0.80 mm
F
Ø1.20 mm
Ø0.80 mm
G
Ø0.95 mm
Ø0.60 mm
Pilot light burner injector
Nr. 36 (SIT
0.977.091)
no 23 (SIT 0.977.150)
Technical specification
66
Gas Fire Panorama 70-55
Summary of Contents for 70-55 PF2
Page 1: ...Installation and maintenance manual Gas Fire Panorama 70 55 PF2 Serial number Production date...
Page 50: ...2 Remove the side panels and front panel Maintenance 50 Gas Fire Panorama 70 55...
Page 71: ...9 3 Gas Fire Panorama 70 55 PF2 with 4 cm frame Dimensions Gas Fire Panorama 70 55 71...
Page 73: ...9 5 Gas Fire Panorama 70 55 PF2 with 6 cm frame Dimensions Gas Fire Panorama 70 55 73...
Page 75: ...9 7 Gas Fire Panorama 70 55 PF2 with 10 cm frame Dimensions Gas Fire Panorama 70 55 75...
Page 78: ...9 10 Operating unit Dimensions 78 Gas Fire Panorama 70 55...
Page 81: ...11 EU Declaration of Conformity EU Declaration of Conformity Gas Fire Panorama 70 55 81...
Page 82: ...EU Declaration of Conformity 82 Gas Fire Panorama 70 55...
Page 83: ...EU Declaration of Conformity Gas Fire Panorama 70 55 83...