1
insulation plate
2
Flammable mantel piece
3
Ceiling
4
Non-flammable spacer
5
Insulation plate back panel
6
Non-flammable false ceiling
7
Insulation plate side panel
8
Insulation plate front panel
Figure 16. Mantel piece clearances
A
Minimum 5 cm from top of glass
B
Flammable ceiling: minimum 60 cm from glass
Non flammable ceiling: minimum 50 cm from glass
C
Mantel piece depth maximum 30 cm
D
Flammable ceiling: minimum 10 cm
Non flammable ceiling: minimum 0 cm
E
Mantel piece depth: maximum 5 cm
F
Minimum 30 cm from top of glass
G
Minimum 5 cm
H
Minimum 10 cm to flammable floor (or put a non flammable hearth plate with a depth
of minimum 30 cm in front of the complete width of the glass)
Clearances
28
Gas Fire Panorama 70-55