![Banner R-GAGE Q130RA Series Instruction Manual Download Page 16](http://html.mh-extra.com/html/banner/r-gage-q130ra-series/r-gage-q130ra-series_instruction-manual_471725016.webp)
7 Specifications
Range
The sensor is able to detect a proper object (see Detectable Objects) at
the following ranges, depending on the target:
9076 models: 1 m to 24 m (3.3 ft to 78.7 ft)
2450 models: 1 m to 40 m (3.3 ft to 131.2 ft)
Detectable Objects
Objects containing metal, water, or similar high-dielectric materials
Operating Principle
Frequency modulated continuous-wave (FMCW) radar
Operating Frequency
24.050-24.250 GHz, ISM Band
Maximum Output Power
ERP: 3.3 mW, 5 dBm
EIRP: 100 mW, 20 dBm
Supply Voltage (Vcc)
12 V dc to 30 V dc
Power and Current Consumption, exclusive of load
Normal Run Mode: 1.2 W, Current consumption < 50 mA at 24 V dc
Supply Protection Circuitry
Protected against reverse polarity and transient overvoltages
Delay at Power-up
< 3 seconds
Output Configuration
Bipolar NPN/PNP output
Load 1 on pin 2 (white wire) = NPN
Load 2 on pin 4 (black wire) = PNP
Output Ratings
50 mA maximum capability each output
Saturation: < 3.5 V at 50 mA
Off-state leakage current:
Outputs specifications per configuration
PNP
Output High
≥ Vsupply - 2.5 V
Output Low
≤ 2.5 V (loads ≤ 70 kΩ)
NPN
Output High
≥ Vsupply - 2.5 V (loads ≤ 70
kΩ)
Output Low
≤ 2.5 V
Output Protection
Protected against short circuit conditions
Response Time
Software selectable:
50 ms ON/50 ms OFF
100 ms ON/100 ms OFF
50 ms ON/500 ms OFF
50 ms ON/1000 ms OFF
Indicators
Power LED: Green (power ON)
Signal Strength LED: Red, flashes in proportion to signal strength.
Steady on at 4x excess gain. Only indicates signal amplitude, not target
distance.
Output LEDs: Amber (output energized)
See
Construction
Housing: ABS/polycarbonate
QD Connector: Stainless steel
Mounting Threads: Stainless steel
Vibration
All models meet IEC 60947-5-2 (Vibration: 10 Hz to 55 Hz; 1 mm peak-
to-peak amplitude; 5 minute duration; 30 minutes in each of the three
axes at resonant frequency or at 55 Hz)
Shock
All models meet IEC 60947-5-2 (Shock: 30G peak acceleration, 11 ms
pulse duration, half sine wave pulse shape)
Operating Temperature
–40 °C to +65 °C (–40 °F to +149 °F)
Environmental Rating
IEC IP67
Connections
Integral 5-pin M12/Euro-style quick disconnect. Models with a quick
disconnect require a mating cordset
Certifications
E224071
UL Environmental Rating: Type 1
ETSI/EN 300 440
FCC ID: UE3RGAGE1XX
for others, contact Banner Engineering
Country of Origin: USA
7.1 FCC Part 15 and CAN ICES-3 (B)/NMB-3(B)
This device complies with part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions:
1.
This device may not cause harmful interference, and
2.
This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). These
limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.
•
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•
Consult the manufacturer.
R-GAGE
®
Q130RA Sensor
16