5 Remote Input
Use the remote input to program the sensor remotely.
The remote input provides limited programming options and is Active Low. Connect the gray input wire to ground (0 V dc),
with a remote switch connected between the wire and ground. Remote teach can also be performed using the button on
the Pro Converter Cable. The remote input wire is disabled by default. Pulse the remote input wire 10 times to enable the
feature. After enabling the remote input feature, pulse the remote input according to the diagram and the instructions
provided in this manual.
To use the Pro Converter Cable for remote input, click
Stop in the Banner Radar Configuration Software before pressing
the button on the cable. The Software cannot be sampling data while remote input is in use.
The length of the individual programming pulses is equal to the value T: 0.04 seconds ≤ T ≤ 0.8 seconds.
Exit remote programming modes by setting the remote input Low for longer than 2 seconds or by waiting for 60 seconds.
1x
2x
Remote Setup
Remote Teach
1x
Teach Output 1 Switch Point
0.04 seconds < T < 0.8 seconds
Timing between Pulse groups > 1 second
Pulse Timing (T)
Gray wire is remote teach input
1x
Output 1 Mode
3x
1x
Signal Strength Threshold = 1
2x
Signal Strength Threshold = 1.13
3x
Signal Strength Threshold = 1.25
4x
Signal Strength Threshold = 1.5
5x
Signal Strength Threshold = 2
6x
Signal Strength Threshold = 5
7x
Signal Strength Threshold = 6.5
8x
Signal Strength Threshold = 7.5
Sensitivity Selection
8x
Reset to Factory Defaults
10x
Enable/Disable Remote Teach
Remote
Input
1x
Switch Point Object Teach (Normally Open)
2x
Switch Point Object Teach (Normally Closed)
3x
Switch Point Background Teach (Normally Open)
4x
Switch Point Background Teach (Normally Closed)
Figure 6. Remote Input Map
Note: If a factory reset is performed through the Banner Radar Configuration Software, the remote input
wire becomes disabled (factory default setting). If the sensor is returned to factory defaults by using the
remote input wire, the input wire remains enabled and the rest of the settings are restored to factory
defaults.
5.1 Teach Output 1 Switch Point
1. Pulse the remote input once. The green power LED flashes slowly.
2. Present the target.
3. Teach the Output 1 switch point.
R-GAGE
®
Q130RA Sensor
12