L-GAGE
®
LT7 Long-Range Time-of-Flight Sensor
14
P/N 120244
Banner Engineering Corp.
•
Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
RS422 Protocol
All commands via the RS422 serial interface have the following structure:
<STX><Command><[Data]><EOT>
The sensor answers all commands as follows:
<NAK>
= the command was not recognized or the data is outside
the limit values.
or
<ACK>
= the command was recognized and executed; the command
requires no return data.
or
<Data>
= the command was recognized and the requested data has
been sent.
RS422 Cable
The RS422 interface is defined as a reliable, serial interface in full duplex mode, with
transfer rates up to 10 MBaud; max. cable length 1,000 m (4,000'). The shielded cable
is connected to the sensor connector and the ground terminal of the control cabinet.
RS422 User Commands and Their Meanings
Command
Data to LT7*
Data from LT7
Meaning
GAP
All parameters in text format:
Get All Parameters
All sensor parameters are displayed:
LT7 $Revision
x.xx$
• Sensor software revision (number)
Pilot laser status
• Pilot laser status (ON/OFF/xx seconds ON)
Serial settings
• Serial settings (see page 13)
Discrete Output Q1 settings
• Discrete output condition
ON: Output high
OFF: Output low
Output mode (see
IM1
,
IM2
)
Limit 1 setting (see
IL1
,
IL2
)
Limit 2 setting (see
IL4
,
IL5
)
Hysteresis (see
IH1
,
IH2
)
Invert status (ON/OFF; see
IN1
,
IN2
)
Discrete Output Q2 settings
Analog Output QA settings
• Analog output condition (Diffuse sensors only)
Value (0 to 4095)
Limit 1 setting (see
IL3
)
Limit 2 setting (see
IL6
)
Invert status (ON/OFF; see
INA
)
Output status
• Output unit of measure (mm or hundredth inch “10MIL”)
Offset status
• Offset setting (in mm or hundredth inch)
Password setting
• Password (enabled/disabled)
Error status
• Error status (see
GSI
)
ECM
—
ACK
Execute Continuous Measurement
Set and triggered by the next request for measured values
GDB
—
Energy value — 0 to -120dB
Gain Level
Indicates the amount of receiving energy
GNR
—
xxxxxxxxxx
Get Serial Number
Emitted as ASCII text (max. 24 characters)
Definitions:
STX
: start transmission (hex 02 or CTRL B)
EOT
: end of text (hex 04 or CTRL D)
NAK
: no acknowledgement (hex 15 or CTRL U)
ACK
: acknowledge (hex 06 or CTRL F)
Command
: 3-digit command (ASCII text)
[Data]
: whole numbers (ASCII text)
In ASCII text (c data), spaces and
capitals/small letters are ignored.