L-GAGE
®
LT7 Long-Range Time-of-Flight Sensor
P/N 120244
11
Banner Engineering Corp.
•
Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
Main
Menu
Procedure
Example Displays
Results
SERIAL <RS422>
See page 13.
RS422 <ENTER>
Dependent on serial connection selection; see page 13.
PASSWORD
<
OFF
>
• Press
PASSWORD
->OFF
• Sensor is ready to accept new password setting.
• If Password is set to ON, password must be entered each
time Programming mode is entered.
• Press or to toggle
between ON and OFF
settings.
• Press to save setting.
PASSWORD
< OFF >
• Sensor saves setting and returns to Main menu.
FACTOR
Y
<PRESET>
• Press to enter Factory
Preset menu.
F-PRESET
->OK
Returns sensor to factory preset conditions.
•
If activated, all previous settings are lost.
• Use Escape function to exit without changing settings.
• Factory settings are:
Teach-In
– Limit value of measurement range; Q1 and Q2
single switching, normally open, analog mode 1, rising
slope
Offset
– 0
Unit
– mm
Serial
– RS422
Password
– OFF
• Use Escape function to leave
settings as they are.
FACTORY
<PRESET>
• Sensor returns to Main menu without changing settings.
• Press to revert to
Factory Preset settings.
F-PRESET
OK!
• Sensor returns to Main menu with factory preset
condtions.
FACTORY
<PRESET>
Run Mode
• Use Escape function to
return to Run mode.
DIST in
4839
• Sensor returns to Main menu with all saved settings.
���
���
���
���
���
���