Ethernet I/O Status
Main Menu > System > Communications > Ethernet I/O > Status
The Ethernet I/O Status screen can be used to verify that the Ethernet wiring has been correctly set up. In addition to
determining if link has been established, incoming and outgoing traffic can be monitored.
Data Export Advanced Screen
Main Menu > System > Communications > Data Export > Advanced
During the Data and Image export operation, the sensor's output channels might become full. This can occur if the
sensor is producing export data (frames) faster than the data can be exported from the device (due to bandwidth limita-
tions) or faster than the client is reading the channel export data. This setting affects how the sensor will behave in this
situation. Select 'Hold READY' to ensure that all frames are transmitted. In this case, the READY signal will remain
inactive (sensor is busy) until the new frame has been added to the channel for transmission. Triggers might be missed
during this time. Select 'Do not hold READY' to cause the sensor to discard the new frame if the channel is full and thus
iVu Plus User's Manual
40
www.bannerengineering.com - tel: 763-544-3164
Online Only - rev. B