Micro Video Lens Models
A
Lens
B
Focusing Window
C
Locking Clip
D Locking Screw
E
Filter Cap (optional)
F
Filter (optional)
NOTE: Filter Kits are available separately.
Adjust the Focus on a C-Mount Lens Model
1. Remove the Lens Enclosure.
2. Adjust focus while monitoring the focus number. To ensure the best image, adjust the focus until the Focus
Number peaks.
3. Replace the Lens Enclosure on the camera.
C-Mount Models
D
C
A
B
E
C
A
C-Mount Lens
B
Lens Enclosure
C
Retainer Ring (optional)
D Filter (optional)
E
Filter Retainer Ring Tool
NOTE: Filter Kits are available separately.
Trigger
Main Menu > Imager > Trigger
A Trigger is a signal that makes the sensor capture an image and inspect it. Use the dropdown list to selectExternal
Trigger, Internal Trigger (default), Free Run, Industrial Ethernet Only, or Command.
•
If Internal Trigger is selected, triggers are based on timed intervals, and you need to select a trigger interval
between 10 and 10000 milliseconds.
NOTE: If the interval is less than the inspection time, then missed triggers will occur.
•
If External Trigger is selected, inspections are triggered in response to an electrical signal on the Trigger input
line.
•
If Free Run is selected, the sensor automatically runs continuous inspections.
•
If Command is selected, the command channel is used to trigger the sensor from a remote device.
•
If Industrial Ethernet Only is selected, trigger commands from the Industrial Ethernet communications channel
only are accepted.
iVu Plus TG Gen2 Series Sensor
P/N 178442 Rev. B
www.bannerengineering.com - Tel: +1-763-544-3164
9