Multiple Inspections

The iVu Plus supports multiple inspections that facilitate storing and controlling up to 30 inspections of different Sensor

Types.

Adding a New Inspection

To Add a new stored inspection:

1. Go to Main Menu > Inspection > Stored Inspections and click Add New.

 

 

2. Select the Sensor Type for the new inspection, and click Next.

 

 

3. Click Done. The newly created inspection will now be the current inspection.

Changing Running Inspections

To change the running inspection:

1. From the Home screen, click the Yellow button in the top center of the screen that displays the currently running

inspection to display all the stored inspections.

 

 

 

iVu Plus TG Gen2 Series Sensor

10

www.bannerengineering.com - Tel: +1-763-544-3164

P/N 178442 Rev. B

Summary of Contents for iVu Plus TG Gen2

Page 1: ...ed Display datasheet P N 179044 iVu Plus TG Gen2 with Remote Display datasheet P N 179045 iVu Plus TG Gen2 Instruction Manual P N 179042 iVu Plus Industrial Ethernet User s Guide P N B_3095133 In addi...

Page 2: ...l shown C Mount model connections are identical Power I O Connections Pin Wire Color Description Direction 1 White Output 1 Output 2 Brown 10 30V dc Input 3 Green Output 2 Output 4 Yellow Strobe Out 5...

Page 3: ...und Input 8 Red Ready Output 9 Orange Output 3 Output 10 Light Blue RS 232 TX Output 11 Black RS 232 Signal Ground Output 12 Violet RS 232 Rx Input Demo Mode The first time you power up the iVu Plus T...

Page 4: ...ck for the presence of some label or marking on a part that may vary in color Match Sensor A Match type sensor is used to verify that a pattern shape or part in any orientation matches a reference pat...

Page 5: ...to USB Load from USB Reset to Defaults Configuration Lock Device Serial I O Data Export Image Export Communications Connection Data to Export Output Format Input Polarity Input Pullup Output Type Outp...

Page 6: ...r icon is located on the lower right of the sensor display on the Home screen and is used to manually capture a new image The Save icon is used to save data to USB drive and is available at the bottom...

Page 7: ...ndicates that the command has been processed without errors Indicates that the incoming entry is stalled no new bytes or end of frame delimiter was not received or client is not reading data on ethern...

Page 8: ...sensor using the clear Focusing Window B 2 Adjust focus while monitoring the focus number To ensure the best image adjust the focus until the Focus Number peaks NOTE Turning the Focusing Window counte...

Page 9: ...ct it Use the dropdown list to selectExternal Trigger Internal Trigger default Free Run Industrial Ethernet Only or Command If Internal Trigger is selected triggers are based on timed intervals and yo...

Page 10: ...New 2 Select the Sensor Type for the new inspection and click Next 3 Click Done The newly created inspection will now be the current inspection Changing Running Inspections To change the running insp...

Page 11: ...access the channels go to Main Menu System Communications Command Channel a bi directional communication protocol that currently supports ASCII and enables other devices to remotely control the iVu Pl...

Page 12: ...N LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND WHETHER ARISING UNDER COURSE OF PERFORMAN...

Reviews: