3.5 Focus Lock Label—Optional
There are five single-use focus lock labels included in the packaging that can be used to protect the focus position from
being changed after the application has been completed.
These are adhesive labels that are designed to be applied over the focus screw.
Figure 10. Focus Lock Label
3.6 Typical Layouts
The following typical layouts refer to system hardware configurations. However, they also require the correct setup of the
software configuration parameters. Dotted lines in the figures refer to optional hardware configurations within the particular
layout. Most examples show the optional, but recommended, TCNM-ACBB1 connection box (see
TCNM-ACBB1 Electrical
Connections
on page 20).
Important:
When using a TCNM-ACBB1 with an ABR 3000:
• The Input setting Line Type must be set to PNP
• The Trigger and Input 2 indicator LED's are not functional in the TCNM-ACBB1 box
• Any input signals to the TCNM-ACBB1 must be PNP current sourcing signals
Important: ABR 3000 readers do not have auxiliary serial interfaces. Therefore neither data monitoring nor
device configuration can be performed through this interface.
ABR 3000 readers can be configured in Barcode Manager through the Ethernet, Main Serial, or USB
interfaces depending on the reader model.
3.6.1 Ethernet Connection
The Ethernet connection is possible in two different layouts. In a Point-to-Point layout the reader is connected to a local
host by using a STP-M12D-4xx cable. There is no need to use a crossover adapter because ABR incorporates an autocross
function.
ABR 3000 Series Barcode Reader
www.bannerengineering.com - Tel: + 1 888 373 6767
11