2.8 Fault flow chart
No
Yes
Fault symptom:
No light in Product indicator or
No light in Network/Bluetooth Indicator
(See LED indication table page 2.2)
Possible causes:
Defective PCB55, Touch Board
Defective 999module, Chassis
Survey of plugs and
pins,
see page 2.12
Check connector
and cable between
PCB35 CN402 and
PCB55 J900
OK?
Connect or replace
defective cable
Replace
999module,
Chassis
Replace PCB55,
Touch Board
Fault symptom:
No adjustment of volume
Possible causes:
Defective PCB55, Touch Board
Defective 999module, Chassis
Check connector
and cable between
PCB35 CN402 and
PCB55 J900
OK?
Connect or replace
defective cable
Replace
999module,
Chassis
Replace PCB55,
Touch Board