2.1.3 Temperature monitoring
Sensors monitor temperature values in many different areas in the APC910. The locations of the temperature
sensors can be seen in "Figure 4: Temperature sensor locations" on page 22. The values listed in "Table 6:
Temperature sensor locations" on page 22 represent the defined maximum temperature
4)
for the respective
measurement point. An alarm is not triggered if this temperature is exceeded. These temperatures can be read in
BIOS or in approved Microsoft Windows operating systems via the B&R Control Center.
Additionally, the hard disks for APC910 systems available from B&R are equipped with S.M.A.R.T, or Self Moni-
toring, Analysis, and Reporting Technology. This makes it possible to read various parameters, for example the
temperature, using software (e.g. HDD thermometer - freeware) in approved Microsoft operating systems (except
Windows CE).
2.1.4 Temperature sensor locations
Sensors indicate temperature values in many different areas in the APC910. The temperatures
5)
can be read in
BIOS (menu item Advanced - OEM Features - System Board Features / CPU Board Features - Temperature
Values) or in Microsoft Windows operating systems via the B&R Control Center
6)
.
For applications that don't use Windows, the temperatures can be evaluated using the B&R implementation guide.
In addition to the implementation guide, there are also MS-DOS sample programs available.
Figure 4: Temperature sensor locations
Position Measurement point
for
Measurement
Max. specified
A
CPU
Ambient temperature of the processor (sensor integrated in the processor)
95°C
B
Board Controller
Board Controller temperature (sensor integrated on the CPU board).
95°C
C
Main memory
Temperature around main memory (sensor integrated on the baseboard).
75°C
D
Board power supply
Board power supply temperature (sensor on the baseboard).
90°C
E
Slide-in compact
Temperature around slide-in compact drive (sensor on baseboard).
Drive-dependent
F
Slide-in drive 1
Temperature of a slide-in drive 1 (the sensor is integrated on the slide-in drive).
Drive-dependent
H
Interface option
Temperature of an interface option (sensor integrated on the interface option)
Depends on in-
terface option
I
Monitor / Panel option Temperature of a monitor / panel option (sensor integrated on the monitor / panel option)
Depends on mon-
itor / panel option
Table 6: Temperature sensor locations
4)
The temperature measured approximates the immediate ambient temperature but may also be influenced by neighboring components.
5)
The measured temperature approximates the immediate ambient temperature, but can be influenced by neighboring components.