Troubleshooting
19
23
22
6
18
29
30
2 Places
4 Places
4 Places
4 Places
4 Places
28
6
20
2 Places
See page 6 for parts list
Trouble-Shooting
1.
Lock slips down in buckle:
Tighten blade mounting screws. If lock on clamp is still not adequate,
reduce tension on tool by setting torque setting on the Drill Dial to a lower number.
2.
Drill clutch releases prematurely:
Make sure Tool is fully seated on Drill (per page 4). If problem
persists, contact BAND-IT technical support.
Note:
To mitigate Drill Clutch wear, do not over-use the Drill Clutch. When tensioning a clamp, let the
Drill Switch go as Tension Block nears its end of travel. Reverse drill and send Tension Block all the way
forward for a second pull on the band.
3.
If tool does not cut off on initial setting:
Step 1: Pull trigger of tool after engaging cutter blade.
Step 2: Increase torque setting slightly, and repeat tensioning band and engaging of cutter blade.
Step 3: Repeat steps 1 and 2 until band cuts.
4
Tension Block
Assembly
Head Unit