- 20 -
It is possible to enable or disable the pre-blinking in the opening and closing phase following the instruc-
tion listed below.
Values goes from 0 to 1
0 = pre-blinking OFF
1= pre-blinking ON
1. Press P1 and P2 simultaneously for three seconds
to begin programming the board.
2. Letter A appear on the display. Scroll the menu with P1
until letter F appears on the display.
Press P2 to confirm.
3. You should see 1 on the display. Scroll the values
with P1 until 2 will appear on the display.
Press P2 to confirm.
4. Select the value from 0 to 1 with P1
and press P2 to confirm.
ATTENTION!!!!!! For security reasons the pre-blinking can be excluded only for the opening phase and not
for the closing phase. The control board has a default setting of 0 = pre-blinking OFF.
Parameter F2: pre-blinking
Values goes from 0 to 1
0 = photocells enabled during the closing phase
1= photocells enabled during the closing and the opening phase
1. Press P1 and P2 simultaneously for three seconds
to begin programming the board.
2. Letter A appear on the display. Scroll the menu with P1
until letter F appears on the display.
Press P2 to confirm.
3. You should see 1 on the display. Scroll the values
with P1 until 3 will appear on the display.
Press P2 to confirm.
4. Select the value from 0 to 1 with P1
and press P2 to confirm.
ATTENTION!!!!!! The control board has a default setting of 0 = photocells enabled during the closing phase.
Parameter F3: enable the photocells also during the opening phase