Values goes from 0 to 9
0 = open gate pilot light
9 = switching off after 4,5 minutes
1. Press P1 and P2 simultaneously for three seconds
to begin programming the board.
2. Letter A appear on the display. Scroll the menu with P1
until letter T appears on the display.
Press P2 to confirm.
3. You should see 1 on the display. Scroll the values
with P1 until 6 will appear on the display.
Press P2 to confirm.
4. Select the value from 0 to 9 with P1
(SEE THE CHART).
5. Press P2 to confirm.
ATTENTION!!!!!! The control board has a default setting of 0 = open gate pilot light.
ATTENTION!!!!!! If the courtesy light will be operated with a remote control it will remain On until the next
impulse from the remote control or until the gate will be closed or opened again.
ATTENTION!!!!!! If the value open gate pilot light will be selected it will not be possible to operate the cour-
tesy light with the remote control.
PARAMETER T6 - Timing for courtesy light
Display
Seconds
0
1
2
3
4
5
6
7
8
9
open gate pilot light
30
60
90
120
150
180
210
240
270
- 13 -