The motor brake it is used to stop the movement of the gate after
the intervention of a Stop command or limit switch command.
Value goes from 0 to 9
0 = brake OFF
1 = braking of 30ms
9 = braking of 270ms
1. Press P1 and P2 simultaneously for three seconds
to begin programming the board.
2. Letter A appear on the display. Scroll the menu with P1
until letter T appears on the display.
Press P2 to confirm.
3. You should see 1 on the display. Scroll the values
with P1 until 8 will appear on the display.
Press P2 to confirm.
4. Select the value from 0 to 9 with P1
(SEE THE CHART).
5. Press P2 to confirm.
ATTENTION!!!!!! The control board has a default setting of 1 = 50 milliseconds.
PARAMETER T8 -
Motor brake
Display
Milliseconds
0
1
2
3
4
5
6
7
8
9
OFF
30
60
90
120
150
180
210
240
270
- 15 -