ENGLISH
25 / 38
0006081053_201805
DETAILS OF PUMPS
1
Solenoid valve (normally closed)
2 Pressure gauge connector and air vent (1/8”G)
3 Pressure adjusting screw
3.1 Remove the nut to access the pressure adjusting screw
(11-14 bar)
4 Return
4.1 Return with inner by-pass dowel
5 Suction
6 Delivery to nozzle
7
Vacuum gauge connector (1/8”G)
7.1 Vacuum gauge connector and internal by-pass dowel
CAUTION / WARNINGS
The pump is preset at a pressure of 12 bar
7
6
2
4.1
3
5
00050601
15
G7A