MODEL
TBG 450LX MC
TBG 510LX MC
TBG 650LX MC
TBG 750LX MC
Maximum natural gas heat power
kW
4800
5100
6500
7500
Minimum natural gas heat power
kW
600
600
600
650
¹) natural gas emissions
mg/kWh
Class 3
Class 3
Class 3
Class 3
Operation
Two-stage progressive
/ modulating
Two-stage progressive
/ modulating
Two-stage progressive
/ modulating
Two-stage progressive
/ modulating
50 Hz natural gas transformer
8kV - 20 mA - 230V
8kV - 20 mA - 230V
8kV - 20 mA - 230V
8kV - 20 mA - 230V
Maximum natural gas heat rate
Stm³/h
508
540
688
794
Minimum natural gas heat rate
Stm³/h
63
63
63
69
Maximum natural gas pressure
hPa (mbar)
500
500
500
500
Minimum natural gas pressure
hPa (mbar)
111
116
125
167
Maximum propane thermal power
kW
4800
5100
6500
7500
Minimum propane thermal power
kW
600
600
600
650
Maximum propane thermal flow rate
Stm³/h
196
209
266
307
Minimum propane thermal flow rate
Stm³/h
25
25
25
27
Maximum propane pressure
hPa (mbar)
500
500
500
500
Minimum propane pressure
hPa (mbar)
131
111
111
117
²)propane emissions
mg/kWh
Class 3
Class 3
Class 3
Class 3
50hz fan motor
kW
9.2
11
15
18.5
Absorbed electrical power* 50hz
kW
10.2
12.1
16.3
19.9
50 Hz power supply voltage
3N~ 380V ± 10%
3N~ 380V ± 10%
3N~ 380V ± 10%
3N~ 380V ± 10%
Protection rating
IP54
IP54
IP54
IP54
Flame detection
IONISATION PROBE IONISATION PROBE IONISATION PROBE IONISATION PROBE
Control box
LME 73...
LME 73...
LME 73...
LME 73...
Air flow rate regulation
MECHANICAL CAM MECHANICAL CAM MECHANICAL CAM MECHANICAL CAM
Operating ambient air temperature
°C
-15 ÷ +40
-15 ÷ +40
-15 ÷ +40
-15 ÷ +40
Sound pressure**
dBA
82
84
84
87
Sound power***
dBA
96
99
99
101
Weight with packaging
kg
259
262
250
310
Weight without packaging
kg
181.5
185
203
235
Calorific power below reference conditions 15° C, 1013 hPa (mbar):
Natural gas: Hi = 9,45 kWh/Stm³ = 34,02 MJ/Stm³
Minimum gas pressure, depending on the type of gas train used for obtaining max. flow rate with null pressure in the combustion chamber.
* Total absorption at start-up with ignition transformer on.
The measurements have been carried out in accordance with EN 15036 - 1 standard.
** The acoustic pressure measured with burner operating at maximum rated thermal output refers to the manufacturer's laboratory environment
conditions and cannot be compared to measurements carried out in different locations.
*** Acoustic pressure was obtained characterizing the manufacturer's laboratory with a sample source; this measurement has a class 2 accu
-
racy (engineering class) with a standard deviation of 1.5 dB(A).
ENGLISH
6 / 46
0006160271_202007
Summary of Contents for 18190010
Page 2: ......
Page 38: ...SCHEMI ELETTRICI ITALIANO 36 46 0006160271_202007 ...
Page 39: ...ITALIANO 37 46 0006160271_202007 ...
Page 40: ...ITALIANO 38 46 0006160271_202007 ...
Page 41: ...ITALIANO 39 46 0006160271_202007 ...
Page 42: ...ITALIANO 40 46 0006160271_202007 ...
Page 43: ...ITALIANO 41 46 0006160271_202007 ...
Page 44: ...ITALIANO 42 46 0006160271_202007 ...
Page 45: ...ITALIANO 43 46 0006160271_202007 ...
Page 46: ...ITALIANO 44 46 0006160271_202007 ...
Page 47: ...ITALIANO 45 46 0006160271_202007 ...
Page 84: ...WIRING DIAGRAMS ENGLISH 36 46 0006160271_202007 ...
Page 85: ...ENGLISH 37 46 0006160271_202007 ...
Page 86: ...ENGLISH 38 46 0006160271_202007 ...
Page 87: ...ENGLISH 39 46 0006160271_202007 ...
Page 88: ...ENGLISH 40 46 0006160271_202007 ...
Page 89: ...ENGLISH 41 46 0006160271_202007 ...
Page 90: ...ENGLISH 42 46 0006160271_202007 ...
Page 91: ...ENGLISH 43 46 0006160271_202007 ...
Page 92: ...ENGLISH 44 46 0006160271_202007 ...
Page 93: ...ENGLISH 45 46 0006160271_202007 ...
Page 95: ......