BTL5-A/C/E/G__-M____-B/Z-S32/KA__

Micropulse Linear Position Transducer

Analog Output-Rod Style

6     Calibration procedure (cont.)

6.1   Selecting calibration mode

System not running:
Depending on the application use
either Teach-in or manual adjust.

System running:
In special situations the online setting
mode may be used.

6.2

   

Teach-in

The factory-set null- and endpoints will
be replaced by the new null- and
endpoints. First move the magnet to
the new null position, then to the new
end position, and press the buttons to
accept the corresponding value.

See Section 7: Teach-in mode

1st step: Move magnet to new
null position

1          2

1

2

1

/ 2

1

1

2

1

1

1

+  2

1

+  2

1

+  2

2  +

1

2

2

2

6.3   Manual adjust

This method allows you to set a new
start and/or end value. This may be
useful if the magnet can not be
brought to the null or end point of the
transducer.

To do this, the magnet is
brought alternately to the new
start and end position, and the
displayed values are adjusted
by keystroke or pressing the
buttons until the desired values
are reached.

See Section 8: Manual adjust
mode

Fig. 6-1: Calibration device

(shown on transducer)

6.4   Reset

The reset function can be used
to restore the transducer to its
factory default settings.

See Section 9:s Resetting all
values (Reset)

6.5  Online-setting

Setting the start and end values
is done while the system
is running.

See Section 10: Online
setting mode

New end
value

New start
value

Null point

Move magnet to new
desired start position.

Move magnet to new

end position

End
point

before

after

before

after

= Button 2
   gray

Teach-in

Adjust

Null

point

End

point

Buttons
disabled

Buttons
enabled

Null

point

End

point

= Button 1
   blue

Reset

Online-
setting

Null point

End point

Buttons
disabled

Buttons
enabled

Online-
setting

1

Fig. 6-4: Manual
adjust procedure

Fig. 6-3: Teach-in procedure

End
value

Accept new

end value

Accept new null value

 rising

Null
value

f

alling

before

after

     2nd step: Move magnet
     to new end position

New stroke 100 %

before

after

2

Z_Analog_122003.pmd

12/11/2003, 3:47 PM

7

Summary of Contents for Micropulse BTL5-A series

Page 1: ...www balluff com Sensors Worldwide Technical Description User s Guide BTL5 A C E G__ M____ B Z S32 KA__ Micropulse Linear Transducer Analog Output Rod Style...

Page 2: ...1 800 543 8390 WWW BALLUFF COM BTL5 A C E G__ M____ B Z S32 KA__ Micropulse Linear Position Transducer Analog Output Rod Style...

Page 3: ...Normal Stroke Length Housing Type Z Standard Rod Style 3 4 x16 UNF mounting threads and 50 8mm null zone B Metric Rod Style M18x1 5 mounting threads and 30mm null zone Connection Type K A 0 5 8 pin q...

Page 4: ...nnel who will perform the installation and setup of the system 1 3 Use and inspection The relevant safety regulations must be followed when using the transducer system In particular steps must be take...

Page 5: ...and magnet ring Fig 3 1 When attaching the transducer to magnetizable materials appropriate measures must be taken to protect against magnetic disturbances Fig 3 1 Note the recommended distance of th...

Page 6: ...ot exceed a tightening torque of 100 Nm For horizontal mounting of transducer with stroke lengths greater than 500 mm the pressure tube should be supported or attached at its end When installing in a...

Page 7: ...g The cable shield must be grounded on the control side i e connected to the protection ground Pin assignments can be found in Table 4 1 Connections on the controller side may vary according to the co...

Page 8: ...er which displays the BTL voltage or current levels is required All settings are done with a mag net within the stroke area Please verify that the absolute null and endpoints are always within the max...

Page 9: ...ht alternately to the new start and end position and the displayed values are adjusted by keystroke or pressing the buttons until the desired values are reached See Section 8 Manual adjust mode Fig 6...

Page 10: ...2 2 1 s Current position value Code Error value New null value New end value Code Null value Code End value Code for Teach in Code Error value Current position value Current position value Current pos...

Page 11: ...i e the slope and the start value can mutually affect each other depending on the stroke position You will need to repeat steps 1 to 8 over until the start and end values agree with their respective d...

Page 12: ...while activating a button please wait for an additional 12 s before starting over Perform reset 3 Hold down both buttons for at least 6 s The Null value is displayed and the reset has taken place 4 Re...

Page 13: ...reases the actual value by approx 1 mV or 2 A Holding a button down for longer than 1 s increases the step size 4 Once the adjustment range or the desired end value is reached the setup mode is automa...

Page 14: ...5 mA Ripple 5 mV BTL5 C Output current 0 20 20 0 mA Load resistance 500 Ohm B T L 5 E Output current 4 20 20 4 mA Load resistance 500 Ohm 11 4 Connection to controller Analog interface With S32 conne...

Page 15: ...cal connection Magnet Thread size B M18 1 5 includes nut Z 3 4 16UNF B 30 mm Z 2 B lind hole M4 4 6 deep Magnet BTL5 B Z KA05 BTL5 B Z S 32 Calibration device Fig 3 2 Transducer BTL5 B Z Dimensions st...

Page 16: ...s Balluff Inc 8125 Holton Drive Florence KY 41042 Phone 859 727 2200 Toll free 1 800 543 8390 Fax 859 727 4823 Web www balluff com E Mail balluff balluff com Canada Balluff Canada Inc 2840 Argentia Ro...

Reviews: