BTS M30E0-_ _ _-H0001-S04G
Infrared Temperature Sensor
30
14
Error Handing and Display
english
Errors are shown by means of an information display on the screen as well as by the LEDs. When multiple errors are
present at the same time, the one with higher priority is displayed.
14.1 Error Displays
Display
Meaning
Indicator LEDs
(flashing)
Priority
indica-
tion
Outputs
Defect/data loss
LED ON
Low -> High priority
Off
(high-impedence)
LED OUT1
LED OUT2
Short circuit on digital output
OUT1
LED ON
LED OUT1
LED OUT2
Short circuit on digital output
OUT2
LED ON
LED OUT1
LED OUT2
IO-Link communication loss
LED ON
LED OUT1
LED OUT2
Overtemperature (sensor
electronics)
LED ON
Off
(high-impedence)
LED OUT1
LED OUT2
Load on analog output is outside
the specification
LED ON
LED OUT1
Note
Pressing any key clears the
display.
LED OUT2
Undervoltage < 10 V
LED ON
Off
(high-impedence)
LED OUT1
LED OUT2
Undervoltage IO-Link <18 V
LED ON
LED OUT1
LED OUT2
14.2 Other Info Displays
Display
Meaning
This function is temporarily unavailable since for example the corresponding IO-Link
function is active.
IO-Link data storage or block parameterizing is active. No local parameterizing is possible.
The device is resetting itself to the factory defaults.
Operating hours counter (individual) is being reset to 0.
Key lock active. Key lock can be lifted by holding down [
▲▼
].