15.8 Teach-In Switchpoints via IO-Link
Note
Teach-In is automatically left 10 min after starting. During this time no teach-in can be started from the opera-
ting keys.
Principle
Switchpoint SPy is determined by teaching two teach points (TP1 and TP2).
Function:
Result:
TP1 = Teaching static object
TP2 = Teaching background
SPy lies between the object and the background
BDCx
Two Value Teach
TP2
T
0
1
TP1
SPy
x = 1, 2 y =1, 2
System commands
SPy Two Value Teach TP1 (Set TP1)
SPy Two Value Teach TP2 (Set TP2)
Teach Apply (Set SPy)
Teach-In Status
Teach Flags
Teach State
SP2
SP1
TP2
TP1
TP2
TP1
Example for:
0 = TP1 of SP2 not taught or not successful
1 = TP1 or SP2 successfully taught
0 = IDLE
1 = SP1 SUCCESS
2 = SP2 SUCCESS
3 = SP12 SUCCESS
4 = WAIT FOR COMMAND
5 = BUSY
6 = reserved
7 = ERROR