background image

www.balluff.com

BTL6-A/E500/B50 _ -M _ _ _ _ -E2/E28-KA _ _ /LA _ _ -ZA _ _

Magnetostrictive Linear Position Sensor – Rod Style

The CE Mark verifies that our products 

meet the requirements of the current 

EMC Directive.

Intended use

The BTL magnetostrictive linear position sensor, together 

with a machine controller (e.g. PLC), comprises a position 

measuring system. It is intended to be installed into a 

machine or system and used in the industrial sector. 

Flawless function in accordance with the specifications in 

the technical data is ensured only when using original 

Balluff accessories. Use of any other components will void 

the warranty.

Opening the BTL or non-approved use are not permitted 

and will result in the loss of warranty and liability claims 

against the manufacturer.

General safety notes

Installation 

and

 startup

 may only be performed by 

trained specialists.

The 

operator

 is responsible for ensuring that local safety 

regulations are observed. In particular, the operator must 

take steps to ensure that a defect in the BTL will not result 

in hazards to persons or equipment.

If defects and unresolvable faults occur in the BTL, take it 

out of service and secure against unauthorized use.

Dimensions and function

The BTL contains the waveguide which is protected by an 

outer stainless steel tube (rod). A magnet is moved along 

the waveguide. This magnet is connected to the system 

part whose position is to be determined. The magnet 

defines the position to be measured on the waveguide.

Downloading further instructions

A complete user’s guide can be downloaded from the 

Internet at 

www.balluff.com

 or requested via e-mail from 

[email protected]

.

See the user’s guide for information on

standard/additional regulations or compatibility

tests for the BTL6.

Electrical connection

Pin

BTL6-…-ZA0N 

BTL6-…-ZA16

BTL6-…-ZA0R 

BTL6-…-ZA17

1

10…30 V DC

2

Not used

1)

Output signal

3

GND

2)

4

Output signal

Not used

1)

Pin assignment (view of 
connector pins of BTL), 

4-pin M12 circular plug

1) Unassigned leads can be connected to GND on the controller side 

but not to the shield.

2) Reference potential for supply voltage and EMC-GND.

Output signal

-A500

-B500

-B502

-B503

-E500

0…10 V

0…5 V

0.25…4.75 V 0.5…4.5 V 4…20 mA

3) Unusable area
4) Not included in scope of delivery

Damping zone

Magnet

3)

Nominal length =
Measuring range

4)

3)

Version

D1

G

...-E2-...

10.2 mm

Thread M4x4/ 

6 deep

...-E28-...

8 mm

No thread

Mounting 

surface 

O-ring
Support ring

1

english

3

Ø D1

G

Ø 48 f7

Ø 38.9

Ø 24

63.5

30

25.2

21

Ø 4.4

25

7.5

4

45°

~13

R2

Ø 46

BTL6-…-KA…-ZA_ _

BTL6-…-LA…-ZA_ _

M12 contact insert

-1

Summary of Contents for BTL6-A Series

Page 1: ...B50_ M_ _ _ _ E2 E28 KA_ _ LA_ _ ZA0R BTL6 A E500 B50_ M_ _ _ _ E2 E28 KA_ _ LA_ _ ZA16 BTL6 A E500 B50_ M_ _ _ _ E2 E28 KA_ _ LA_ _ ZA17 deutsch Kurzanleitung english Condensed guide fran ais Notice...

Page 2: ...r bewegt Dieser Positionsgeber ist mit dem Anlagen bauteil verbunden dessen Position bestimmt werden soll Der Positionsgeber definiert die zu messende Position auf dem Wellenleiter Download weiterer A...

Page 3: ...ohrung muss perfekt abgedichtet sein O Ring Flachdichtung Das BTL kann in einer Passbohrung 48 H8 befestigt werden wobei die Abdichtung mit dem mitgelieferten O Ring und St tzring erfolgt Der K rper d...

Page 4: ...elt BCC M425 0000 1A 014 PS0434 Pin Farbe 1 BN Braun 2 WH Wei 3 BU Blau 4 BK Schwarz Inbetriebnahme GEFAHR Unkontrollierte Systembewegungen Bei der Inbetriebnahme und wenn das Positionsmess systemTeil...

Page 5: ...cure against unauthorized use Dimensions and function The BTL contains the waveguide which is protected by an outer stainless steel tube rod A magnet is moved along the waveguide This magnet is connec...

Page 6: ...result in increased wear The mounting surface of the BTL must make full contact with the supporting surface The bore must be perfectly sealed O ring flat seal The BTL can be fastened in a fitting bore...

Page 7: ...se fields Accessories PUR cable 4 wire shielded molded Straight BCC M415 0000 1A 014 PS0434 Example with 5 m BCC M415 0000 1A 014 PS0434 050 Angled BCC M425 0000 1A 014 PS0434 Pin Color 1 BN Brown 2 W...

Page 8: ...uide d ondes qui est prot g par un tube en acier inoxydable Un capteur de position se d place le long du guide d ondes Le capteur de position est reli l l ment de l installation dont la position doit...

Page 9: ...ra ner une usure pr matur e La surface d appui du BTL doit parfaitement couvrir la surface de r ception Le per age doit tre parfaitement tanche joint torique plat Le BTL peut tre fix un per age d ajus...

Page 10: ...blind extrud Droit BCC M415 0000 1A 014 PS0434 Exemple avec 5 m BCC M415 0000 1A 014 PS0434 050 Coud BCC M425 0000 1A 014 PS0434 Broche Couleur 1 BN Marron 2 WH Blanc 3 BU Bleu 4 BK Noir Mise en servi...

Page 11: ...otetto contro l uso non autorizzato Dimensioni e funzionamento Nel BTL si trova la guida d onda protetta da un tubo in acciaio inox Lungo la guida d onda viene spostato un datore di posizione Questo d...

Page 12: ...TL deve poggiare completamente sulla superficie di alloggiamento Il foro deve essere perfettamente chiuso a tenuta O ring guarnizione piatta Il BTL pu essere fissato in un foro di riferimento 48 H8 e...

Page 13: ...415 0000 1A 014 PS0434 Esempio con 5 m BCC M415 0000 1A 014 PS0434 050 Angolo BCC M425 0000 1A 014 PS0434 Pin Colore 1 BN Marrone 2 WH Bianco 3 BU Blu 4 BK Nero Messa in funzione PERICOLO Movimenti in...

Page 14: ...quier uso no autorizado Dimensiones y funcionamiento En el BTL se encuentra el gu aondas protegido mediante un tubo de acero inoxidable A lo largo del gu aondas se mueve un sensor de posici n Este sen...

Page 15: ...gaste La superficie de contacto del BTL debe coincidir completamente con la superficie de alojamiento El orificio debe estar perfectamente hermetizado junta t rica junta plana El BTL puede fijarse en...

Page 16: ...indado revestido recto BCC M415 0000 1A 014 PS0434 Ejemplo con 5 m BCC M415 0000 1A 014 PS0434 050 acodado BCC M425 0000 1A 014 PS0434 Pin Color 1 BN Marr n 2 WH Blanco 3 BU Azul 4 BK Negro Puesta en...

Page 17: ...ervice balluff de BTL6 BTL6 ZA0N BTL6 ZA16 BTL6 ZA0R BTL6 ZA17 1 10 30 V DC 2 1 3 GND2 4 1 4 M12 1 GND 2 EMC GND A500 B500 B502 B503 E500 0 10 V 0 5 V 0 25 4 75 V 0 5 4 5 V 4 20 mA 3 4 3 4 3 D1 G E2 1...

Page 18: ...0 B50_ M_ _ _ _ E2 E28 KA_ _ LA_ _ ZA_ _ 1 M12 2 SW 8 4 M12 4 2 mm 2 3 4 4 IP67 BTL BTL BTL 48 H8 O 3 M5 BTL 120 500 mm 10 2 mm 10 2 mm 13 mm 8 mm 11 mm 4 20 5 3 M12x1 13 3 0 10 0 00 14 20 3 2 4 2 SW...

Page 19: ..._ LA_ _ ZA_ _ 3 1 2 3 BTL BTL BTL BTL EMC BTL EMC BTL6 ZA0R BTL6 ZA0N M12 4 BTL6 ZA16 BTL6 ZA17 M12 4 l BTL EMC BTL 85 BTL BTL BTL BTL6 KA_ _ 3 x 2 m5 5 PUR BCC M415 0000 1A 014 PS0434 5 m BCC M415 0...

Page 20: ...9 73765 Neuhausen a d F Phone 49 7158 173 370 Fax 49 7158 173 691 service balluff de US Service Center USA Balluff Inc 8125 Holton Drive Florence KY 41042 Phone 859 727 2200 Toll free 1 800 543 8390...