BTL5-T1_ _-M_ _ _ _-B/Z-S103
Micropulse Linear Transducer - Rod Style
18
english
7
Configuration (cont.)
Octet No. Name
Type
Description
Offset Settings
35-38
Preset_Position_1
UINT32
Output value Position 1 is set to Preset_Position_1
(with respect to octet 19-22). Default Value = 0
39-42
Preset_Position_2
UINT32
Output value Position 2 is set to Preset_Position_2
(with respect to octet 19-22). Default Value = 0
43-46
Preset_Position_3
UINT32
Output value Position 3 is set to Preset_Position_3
(with respect to octet 19-22). Default Value = 0
47-50
Preset_Position_4
UINT32
Output value Position 4 is set to Preset_Position_4
(with respect to octet 19-22). Default Value = 0
If high limit = low limit, monitoring function not active
51-54
Low_Limit_Position_1
INT32
Switch point for position 1 work area low limit
(with respect to octet 19-22). Default Value = 0
55-58
Low_Limit_Position_2
INT32
Switch point for position 2 work area low limit
(with respect to octet 19-22). Default Value = 0
59-62
Low_Limit_Position_3
INT32
Switch point for position 3 work area low limit
(with respect to octet 19-22). Default Value = 0
63-66
Low_Limit_Position_4
INT32
Switch point for position 4 work area low limit
(with respect to octet 19-22). Default Value = 0
67-70
High_Limit_Position_1
INT32
Switch point for position 1 work area high limit
(with respect to octet 19-22). Default Value = 0
71-74
High_Limit_Position_2
INT32
Switch point for position 2 work area high limit
(with respect to octet 19-22). Default Value = 0
75-78
High_Limit_Position_3
INT32
Switch point for position 3 work area high limit
(with respect to octet 19-22). Default Value = 0
79-82
High_Limit_Position_4
INT32
Switch point for position 4 work area high limit
(with respect to octet 19-22). Default Value = 0
If high limit = low limit, monitoring function not active
83-86
Low_Limit_Speed_1
INT32
Switch point for speed 1 low limit (with respect to octet 27-30).
Default Value = 0
87-90
Low_Limit_Speed_2
INT32
Switch point for speed 2 low limit (with respect to octet 27-30).
Default Value = 0
91-94
Low_Limit_Speed_3
INT32
Switch point for speed 3 low limit (with respect to octet 27-30).
Default Value = 0
95-98
Low_Limit_Speed_4
INT32
Switch point for speed 4 low limit (with respect to octet 27-30).
Default Value = 0
99-102
High_Limit_Speed_1
INT32
Switch point for speed 1 high limit (with respect to octet 27-30).
Default Value = 0
103-106 High_Limit_Speed_2
INT32
Switch point for speed 2 high limit (with respect to octet 27-30).
Default Value = 0
107-110 High_Limit_Speed_3
INT32
Switch point for speed 3 high limit (with respect to octet 27-30).
Default Value = 0
111-114 High_Limit_Speed_4
INT32
Switch point for speed 4 high limit (with respect to octet 27-30).
Default Value = 0
Table 7-2b: Parameter data