BTL5-T1_ _-M_ _ _ _-B/Z-S103
Micropulse Linear Transducer - Rod Style
20
english
7
Configuration (cont.)
Table 7-4b: Diagnostic data
Octet No. Name
Type
Description
Encoder Class 1 (continued)
9
Operation_status
BYTE
Bit 0
Code Sequence Status
0 =
1 =
Lower position values
at connector side
Higher position values
at connector side
Bit 1
Class 2 Functionality Status
0 =
1 =
No, not supported
Yes
Bit 2
Commissioning Diagnostics
Status
Bit 3
Scaling Function Status
0 =
1 =
Disabled
Enabled
Bit 4-7
Reserved
10
Encoder_type
BYTE
Default Value 0x07 - Absolute Linear Encoder
11-14
Position_measuring_step
UINT32 LSB in steps of 0.001 µm
Default Value = 0x3E8
→
1 µm engeneering resolution
15-16
Number_of_distinguishable_
revolutions
UINT16 Default Value = 1
→
single turn encoder
Encoder Class 2
17
Additional_Alarms
OCTET
Reserved (Class 2), refer to PROFIBUS, Profile for Encoder
18-19
Supported_Alarms
OCTET
20-21
Warnings
OCTET
22-23
Supported_Warnings
OCTET
24-25
Profile-Version
OCTET
26-27
Software-Version
OCTET
28-31
Operating-Time
UINT32
32-35
Offset_Value
INT32
36-39
Manufacturer_Offset_Value
INT32
40-43
Measuring_Units_Per_Revolution
UINT32
44-47
Total_Measuring_Range
UINT32
48-57
Serial_Number
STRING
58-59
Reserved
BALLUFF Extensions
60
Pointer_State
BYTE
Bit 0
Magnet 1
0 =
1 =
Pointer (Magnet) not available
Pointer (Magnet) available
Bit 1
Magnet 2
Bit 3
Magnet 3
Bit 4
Magnet 4
Bit 5-7
Reserved
61
Position_State
BYTE
Bit 0-1
Magnet 1
Dual Bit Information
Bit 2-3
Magnet 2
00 =
01 =
10 =
11 =
Pointer (Magnet) inside work area
Pointer (Magnet) outside work area,
value lower than low limit
Pointer (Magnet) outside work area,
value greater than high limit
Not possible
Bit 4-5
Magnet 3
Bit 6-7
Magnet 4
62
Speed_State
BYTE
Bit 0-1
Magnet 1
Dual Bit Information
Bit 2-3
Magnet 2
00 =
01 =
10 =
11 =
Speed value inside defined work area
Speed value lower than speed low limit
Speed value greater than speed high limit
Not possible
Bit 4-5
Magnet 3
Bit 6-7
Magnet 4