BTL5-T1_ _-M_ _ _ _-B/Z-S103
Micropulse Linear Transducer - Rod Style
english
In a second step the function mod-
ules are assigned to the device. To
do this, select the device in the
graphic. Next drag and drop the
desired module from the hardware
catalog into the tabular device con-
figuration.
➥
➥
➥
➥
➥
Fig. 7-15
Double clicking on the module in
the tabular representation of the
device configuration opens the cor-
responding dialog for parameter
assignment.
➥
➥
➥
➥
➥
Fig. 7-16
The .parameter assignment for the
BTL is done on the 'Parameter as-
signment' tab.
Depending on the module selected
the parameter number shown may
differ. By default the BTL is set to an
7
Configuration (cont.)
Fig. 7-16: 'Parameter assignment' tab
Fig. 7-17: Hex representation of the parameter data
internal working resolution of 5 µm
(parameter 'Pos. Revolution Unit').
The external output resolution is
1 µm (parameter 'Pos. Engineering
Unit'). The velocity is set to
0.1 mm/s. The following settings
always refer to the set output reso-
lution.
The [ Hex ] button allows you to
represent the parameter data in hex
format. This function is not however
needed under normal circum-
stances, and is used mainly for di-
rect comparison of the parameter
data with the parameter tables
shown in this manual.
➥
➥
➥
➥
➥
Fig. 7-17