BTL5-T1_ _-M_ _ _ _-B/Z-S103
Micropulse Linear Transducer - Rod Style
12
english
Depending on the module selected
the parameter number shown may
differ. By default the BTL is set to an
internal working resolution of 5 µm
(parameter 'Pos. Revolution Unit').
The external output resolution is 1
µm (parameter 'Pos. Engineering
Unit'). The velocity is set to 0.1 mm/
s. The following settings always
refer to the set output resolution.
7
Configuration (cont.)
Fig. 7-10: Parameterizing the BTL5-T...
The [ Hex ] button allows you to
represent the parameter data in hex
format. This function is not however
needed under normal circum-
stances, and is used mainly for di-
rect comparison of the parameter
data with the parameter tables
shown in this manual.
➥
➥
➥
➥
➥
Fig. 7-11
7.4
Configuring using
Siemens Step7
To set parameters for the BTL5-T
using Step7 configuration software,
be sure that Step7 Version 5 or
higher with Service Pack 3 is used.
7.4.1 Import BTL5-T
To use the BTL5-T in the Step7
hardware configurator, the GSD file
must be imported to the system
using the menu point 'Extras'
→
'Install new GSD'. When updating
the GSD file be sure that no appli-
cation is currently using the GSD
file, since otherwise the system
cannot exchange the file.
➥
➥
➥
➥
➥
Fig. 7-12
Fig. 7-11: Hex representation of the parameter data