16
english
The specifications are typical values for
BTL PF _ 400- _ _ _ _ -C12NL _ _ -0-000S04 with 24 V DC
and at room temperature and with a measuring length of
500 mm in conjunction with the magnet BTL5-P-3800-2,
BTL5-P-4500-1, BTL5-P-5500-2, BTL6-A-3800-2,
BTL6-A-3801-2, BTL5-F-28141-S or BTL5-T-28141-S.
The product is immediately ready for operation, full
accuracy is achieved after the warm-up phase.
Further data can be found at
www.balluff.com
on the product page.
9.1
Ambient conditions
Ambient temperature
−25…+85 °C
Storage temperature
−40…+100 °C
Relative humidity
≤ 90%,
non-condensing
Typ. temperature coefficient
1)
≤ 30 ppm/K
Shock rating as per
EN 60068-2-27
2), 3)
100 g/6 ms
Continuous shock per
EN 60068-2-27
2), 3)
50 g/2 ms
Vibration per EN 60068-2-6
2), 3)
12 g, 10 …2000 Hz
Protection per IEC 60529 (when
threaded together)
IP67
9.2
Detection range/Measuring range
Measuring length
25...4000 mm
Resolution
5 μm
Repeat accuracy
≤ ±10 µm
Length-dependent measuring
frequency
Measuring length ≤ 1270 mm
1000 Hz
Measuring length > 1270 to
≤ 2650 mm
500 Hz
Measuring length > 2650 mm
250 Hz
Non-linearity
≤ ± 50 µm
Detectable speed
≤ 10 m/s
9.3
Electrical data
Operating voltage U
b
18…30 V DC
Current draw (at 24 V DC)
≤ 60 mA
Power consumption
≤ 1.5 W
Overvoltage protection
U
b
up to 36 V DC
Voltage-proof up to (GND – Housing)
500 V DC
9.4
Electrical connection
Short circuit protection
Signal output to
GND and
30 V DC
Polarity reversal protected
U
b
up to 30 V DC
9.5
Interface
IO-Link version
1.1
Transmission rate
COM2 (38.4 kBaud),
COM3 (230.4 kBaud)
Cycle Time
≥ 1 ms
Data format
32 Bit signed
Error value
0x7FFFFFFC
9.6
Materials
Housing material
Aluminum
Cover material
Zinc die cast, galvanized
9.7
Mechanical features
Housing height
20.8 mm
Weight (depends on length)
Approx. 1 kg/m
1)
Measuring length 500 mm, magnet in the middle of the measuring range
2)
Individual specifications as per Balluff standard
3)
Resonant frequencies excluded
9
Technical data
BTL PF _ 400- _ _ _ _ -C12NL _ _ -0-000S04
Magnetostrictive Linear Position Sensor – Profile Style
Summary of Contents for BTL PF 400 Series
Page 2: ...www balluff com ...
Page 3: ...BTL PF_400 ____ C12NL__ 0 000S04 Betriebsanleitung deutsch ...
Page 4: ...www balluff com ...
Page 23: ...BTL PF_400 ____ C12NL__ 0 000S04 User s Guide english ...
Page 24: ...www balluff com ...
Page 43: ...BTL PF_400 ____ C12NL__ 0 000S04 Notice d utilisation français ...
Page 44: ...www balluff com ...
Page 63: ...BTL PF_400 ____ C12NL__ 0 000S04 Manuale d uso italiano ...
Page 64: ...www balluff com ...
Page 83: ...BTL PF_400 ____ C12NL__ 0 000S04 Manual de instrucciones español ...
Page 84: ...www balluff com ...
Page 103: ...BTL PF_400 ____ C12NL__ 0 000S04 Manual de Instruções português ...
Page 104: ...www balluff com ...
Page 123: ...BTL PF_400 ____ C12NL__ 0 000S04 操作手册 中文 ...
Page 124: ...www balluff com ...
Page 143: ...BTL PF_400 ____ C12NL__ 0 000S04 사용 설명서 한국어 ...
Page 144: ...www balluff com ...
Page 163: ...BTL PF_400 ____ C12NL__ 0 000S04 取扱説明書 日本語 ...
Page 164: ...www balluff com ...
Page 183: ...BTL PF_400 ____ C12NL__ 0 000S04 Руководство по эксплуатации русский ...
Page 184: ...www balluff com ...
Page 203: ......