www.balluff.com
21
4
IO-Link Interface
4.4.
Parameter data
/ Request data
DPP
ISDU
Object name
Length
Range
Default value
Index Index
Sub-
Index
Ident
if
ic
a
ti
on
dat
a
07
hex
Vendor ID
2 bytes
read only
0378
hex
08
hex
09
hex
Device ID
3 bytes
050204
hex
0A
hex
10
hex
0
Vendor name
7 bytes
BALLUFF
11
hex
0
Vendor text
15 bytes
www.balluff.com
12
hex
0
Product name
20 bytes
BNI IOL-719-002-Z012
13
hex
0
Product ID
7 bytes
BNI00AJ
14
hex
0
Product text
32 bytes
Sensorhub Analog, 8
Analog Input
15
hex
0
Serial Nr
16 bytes
16
hex
0
Hardware Revision
1 byte
17
hex
0
Firmware Revision
18
hex
0
Application specific
tag
32 bytes
P
a
ra
m
e
te
r
dat
a
54
hex
0
Serial number
16 bytes
16x 00
hex
59
hex
0
Process data
alignment
1 byte
0..1
1
F0
hex
0
1-8
Analog mode
8 bytes
0
hex
FF
hex
FF
hex
F1
hex
0
1-8
Resolution
8 bytes
0..3
0
F2
hex
0
1-8
Pin assignment
8 bytes
0..3
1
F3
hex
0
1-8
Pt100/ Pt1000 mode
8 bytes
0..3
3
F4
hex
0
Wirebreak detection
enable
1 byte
0..1
0
F5
hex
0
1-8
Process data format
8 bytes
0..2
0
F6
hex
0
1-8
Switch Point 1
16 bytes
0
hex
-
FFFF
hex
0
F7
hex
0
1-8
Switch Point 2
16 bytes
0
hex
-
FFFF
hex
0
F8
hex
0
1-16
Switch Point Enable
2 bytes
0
hex
-
FFFF
hex
0
F9
hex
0
1-8
Thermocouple
grounding
8 bytes
0
hex
FB
hex
0
1-8
Wirebreak detection
8 bytes
0..1
0
Note
To ensure the operation and detection of the sensor, the minimum current
consumption should be at least 10 mA.
Summary of Contents for BNI IOL-719-002-Z012
Page 1: ...BNI IOL 719 002 Z012 english User s Guide deutsch Betriebsanleitung...
Page 2: ...www balluff com...
Page 3: ...BNI IOL 719 002 Z012 Bedienungsanleitung...
Page 37: ...BNI IOL 719 002 Z012 User s Guide...
Page 71: ...BNI IOL 719 002 Z012...
Page 104: ...IO Link BNI IOL 719 002 Z012 www balluff com 33...