24
english
5
Display (continued)
5.12 General information
– Hold down the arrow button to scroll quickly in Edit
mode.
– If no button is pressed for more than 10 seconds, the
display returns to the standard display (4th octet of the
IP address). Unsaved changes may be lost.
– Differences between the new configuration and the
configuration with which the module works are
displayed with an unequal symbol. In this case the
display returns to the standard display after 5 seconds.
– The display flashes in Edit mode. The display flickers in
Fast Scroll mode.
– If the module receives an individual ping, the word
ping
is shown on the display for several seconds. Then the
display returns to the previous display. Ping mode can
be exited early by briefly pressing the Set button.
– If the module receives a double ping or more, the word
ping
appears on the display. The display can only be
exited by briefly pressing the Set button. The display
returns to the display before the ping.
– The LED function of the display LEDs can be defined
specific to the user by setting several bits in the
process data outputs (see bit layout in
– The
plc-lock
function can also be used by setting a bit
in the process data outputs (see bit layout in
).
Edit mode cannot be selected in the display if in
the process data inputs the
plc-lock
is set by a bit
).
BNI EIP-508-105-Z067
Network interface
Summary of Contents for BNI EIP-508-105-Z067
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BNI EIP 508 105 Z067 ...
Page 2: ...www balluff com ...
Page 3: ...BNI EIP 508 105 Z067 Konfigurationsanleitung deutsch ...
Page 4: ...www balluff com ...
Page 45: ...BNI EIP 508 105 Z067 Configuration Guide english ...
Page 46: ...www balluff com ...
Page 87: ......