3
Configuration via Explicit Messages (continued)
3.2
Example with Rockwell components
Fig. 3-1:
1756-L6xS
1756-EN2T
Electrical
Lock Signal
Stratix 8000
Managed Switch
Power
Supply
Tool Changer
QuickConnect Armor-
Block I/O Modules
I/O Modules
System components (example)
Please note the following:
– Direct connection between PLC and QuickConnect
slave with crossover cable
– Connection from slave to slave with patch cable
– For the topology structure only the linear topology with
maximum 20 modules is permitted on the tool side.
– If required, only one Managed Switch may be used
between PLC and Ethernet/IP slave.
– An Electrical Lock Signal is required for triggering the
QuickConnect sequence, which reads the supply
voltage of the QuickConnect slaves via the control.
3.3
PLC program
Information about the PLC program and
Add
Application Logic
, see Allen Bradley Ethernet/IP
QuickConnect Application Technique.
BNI EIP-508-105-Z067
Network interface