www.balluff.com
11
english
3
Configuration via Explicit Messages
3.1
QuickConnect
The BNI EIP-508-105-Z067 module can be started and
integrated quicker using the QuickConnect function.
All necessary port properties of the module are
automatically applied with activation of QuickConnect:
– Static IP address
– Ports on 100 Mbit/s full-duplex
– Autonegotiation deactivated
– Auto MDIX deactivated
– Prepared for linear topology
Set QuickConnect using the following values of the
Explicit
Messages
:
Class
Instance
Attribute
Value
245 (0xF5)
1 (0x01)
12 (0x0C)
0: disabled
(default)
1: enabled
Tab. 3-1: Possible values for Quick Connect
The ACD (Address Conflict Detection) must also
be activated to enable QuickConnect. This is
switched on by default.
The ACD (Address Conflict Detection) can be checked and
changed via the following Class Instance Attribute of the
Explicit Messages
:
Class
Instance
Attribute
Value
245 (0xF5)
1 (0x01)
10 (0x0A)
0: disabled
1: enabled
(default)
Tab. 3-2: Class Instance Attribute of the Explicit Messages
BNI EIP-508-105-Z067
Network interface
Summary of Contents for BNI EIP-508-105-Z067