BIS V-6111 CC-Link
Processor unit
48
english
5. Copying data from one data carrier to another
The data from one data carrier at a read/write head (source) is copied to a data carrier in front of
another read/write head (target). The data carriers have to be in front of the read/write heads
(even if dynamic mode has been configured) and must have the specified address range. The
command is processed in the buffer of the source head.
In the example, 17 words starting from address 10 of the data carrier are to be copied to the
data carrier in front of read/write head 3 starting from address 35.
Control
Identification system
1.
Process output buffer
(note sequence):
2.
(note sequence)
0000
hex
Command designator
0011
hex
RXm1
Set AA bit
0001
hex
Source start address
000A
hex
RXm2
Set AE bit
0002
hex
Target start address
0023
hex
0003
hex
Number of words 0011
hex
0004
hex
Target head number
0003
hex
RYm0
Set AV bit
3.
4.
RYm0
Reset AV bit
RXm1
Reset AA bit
RXm2
Reset AE bit
7
Device Function