www.balluff.com
BIS V-6111 CC-Link
Processor unit
35
english
Command designator 0081
hex
: Read data carrier with 24-bit address assignment
Subaddress
Meaning
Function description
0000
hex
Command
designator
0081
hex
: Read data carrier
0001
hex
Start address (low
word)
Start address for reading.
0002
hex
Start address (high
word)
Start address for reading.
0003
hex
Number of words
(low word)
Number of words to be read starting from the start
address.
0004
hex
Number of words
(high word)
Number of words to be read starting from the start
address.
Command designator 0082
hex
: Write data carrier with 24-bit address assignment
Subaddress
Meaning
Function description
0000
hex
Command
designator
0082
hex
: Write to data carriers
0001
hex
Start address (low
word)
Start address to be written from
0002
hex
Start address (high
word)
Start address to be written from
0003
hex
Number of words
(low word)
Number of words to be written starting from the start
address.
0004
hex
Number of words
(high word)
Number of words to be written starting from the start
address.
Command designator 0087
hex
: Saving the start address for the Auto Read function with
24-bit address assignment
Subaddress
Meaning
Function description
0000
hex
Command
designator
0087
hex
: Store the start address for the "Auto Read"
function in EEPROM.
0001
hex
Start address (low
word)
Address for the "Auto Read" function starting from which
the data carrier is read. The value is stored in the
EEPROM.
0002
hex
Start address (high
word)
Address for the "Auto Read" function starting from which
the data carrier is read. The value is stored in the
EEPROM.
7