BIS V-6111 CC-Link
Processor unit
38
english
The structure of the process data buffer is identical for all commands.
Subaddress
Meaning
Function description
0000
hex
Data
Transmission of data that was read from the data
carrier.
0001
hex
Data
Transmission of data that was read from the data
carrier.
0002
hex
Data
Transmission of data that was read from the data
carrier.
…
Data
Transmission of data that was read from the data
carrier.
In case of error:
Subaddress
Meaning
Function description
0000
hex
Error
Error code
Status codes
Note
Status codes are only valid in connection with the AF bit!
Status code
Function description
0000
hex
Everything OK
0001
hex
Job cannot be run because there is no data carrier in range of the read/write
head.
0002
hex
Cannot read the data carrier.
0003
hex
Data carrier was removed from the R/W head's range during reading.
0004
hex
Cannot write to the data carrier.
0005
hex
Data carrier was removed from the R/W head's range during writing.
0007
hex
No or invalid command designator with set AV bit (of the output buffer, see
page 31) or the number of bytes is 00
hex
.
0009
hex
R/W head cable break or no R/W head connected.
000D
hex
Communication to the R/W head disrupted.
000E
hex
CRC for the read data and CRC for the data carrier do not agree.
000F
hex
1st and 2nd bit header are unequal. The 2nd bit header must be used.
0020
hex
Address assignment of the read/write job is outside the memory range of the
data carrier.
0021
hex
This function is not possible for this data carrier.
7