www.balluff.com
BIS V-6111 CC-Link
Processor unit
33
english
Command designator 0007
hex
: Store the start address for the "Auto Read" function
Subaddress
Meaning
Function description
0000
hex
Command
designator
0007
hex
: Store the start address for the "Auto Read"
function in EEPROM.
0001
hex
Start address
Address for the "Auto Read" function starting from which
the data carrier is read. The value is stored in the
EEPROM.
Command designator 0009
hex
: Type and serial number
Subaddress
Meaning
Function description
0000
hex
Command
designator
0009
hex
: Read the read/write head type, data carrier type
and UID (unique identifier) of a data carrier in the field (for
data format, see page 20).
Command designator 0011
hex
: Copy data between data carriers
Subaddress
Meaning
Function description
0000
hex
Command
designator
0011
hex
: Copy data between data carriers
0001
hex
Source start
address
Copy the start address of the source data carrier for the
function from which copying is to start.
0002
hex
Target start address Copy the start address of the target data carrier for the
function from which copying is to start.
0003
hex
Number of words
Number of words to be copied starting from the source
start address.
0004
hex
Target R/W head
number
Number of the read/write head that the target data
carrier is in front of.
Command designator 0012
hex
: Initialize CRC_16 data check
Subaddress
Meaning
Function description
0000
hex
Command
designator
0012
hex
: Initialize CRC_16 data check
0001
hex
Start address
Start address from which the CRC_16 data check is to
be carried out.
0002
hex
Number of words
Number of words for which a CRC_16 data check is to
be carried out from the start address (low word).
7
Device Function