www.balluff.com
BIS V-6111 CC-Link
Processor unit
41
english
Read times in static mode
Data carrier with 32 bytes per block
No. of bytes
Read time [ms]
0 to 31
110
for each additional start of a 32-byte block
120
Data carrier with 64 bytes per block
No. of bytes
Read time [ms]
0 to 63
220
for each additional start of a 64-byte block
230
Write times in static mode
Data carrier with 32 bytes per block
No. of bytes
Read time [ms]
0 to 31
110 + n * 10
≥ 32 bytes
y * 120 + n * 10
Data carrier with 64 bytes per block
No. of bytes
Read time [ms]
0 to 63
220 + n * 10
≥ 64 bytes
Y * 230 + n * 10
n = Number of contiguous bytes to write
y = Number of blocks to process
Example: 17 bytes should be written starting at address 187. Data carrier = 32 bytes per block.
Blocks 5 and 6 are processed, since the start address 187 is in block 5 and end address 203 is
in block 6.
t = 2 * 120 + 17 * 10 = 410
For read/write
heads BIS C
7
Device Function