4-12 Input / Output
MN1903
4.4.3 Digital inputs - X3
Digital inputs DIN0 to DIN3 can be used as high speed position latches. The fast position
inputs are routed through a programmable cross-point switch which allows any input to cause
the position of any combination of axes to be captured (by the hardware) within 1µs. Special
MintMT keywords (beginning with the letters
FAST
...) allow specific functions to be performed
as a result of fast position inputs becoming active.
Location
Breakout module, connector X3
Pin Name
MintMT
keyword
/ description
1 DIN0
INX.0
2 Common1
Common connection
3 Shield
Shield connection
4 DIN1
INX.1
5 Common1
Common connection
6 Shield
Shield connection
7 DIN2
INX.2
8 Common1
Common connection
9 Shield
Shield connection
10 DIN3
INX.3
11 Common1
Common connection
12 Shield
Shield connection
Description
Four fast position digital inputs.
Sampling frequency: 1kHz (MintMT)
Note:
Digital inputs DIN0 to DIN3 are particularly sensitive to noise, so inputs must use
shielded twisted pair cable.
Active high:
DIN
x
= 12-24VDC (±20%)
Common1
= 0V
Common1
DIN
x
MintMT
Vcc
NextMove PCI
Active low:
DIN
x
= 0V
Common1
= 12-24VDC (±20%)
3k3
TLP115
Figure 4 - Digital input circuit - fast interrupts
1
12
Summary of Contents for NextMove PCI
Page 1: ...NextMove PCI Motion Controller MOTION CONTROL Installation Manual 3 02 MN1903...
Page 2: ......
Page 6: ...iv Contents MN1903...
Page 16: ...3 4 Basic Installation MN1903...
Page 42: ...4 26 Input Output MN1903...
Page 57: ...Operation 5 15 MN1903 Figure 11 The NextMove PCI servo loop...
Page 74: ...5 32 Operation MN1903...
Page 90: ...A 8 Accessories MN1903...
Page 91: ......