Input / Output 4-7
MN1903
4.3.2 Analog outputs (Drive Demand/Command) - X7
Location
Breakout module, connector X7
Pin Name
Description
1 Demand0
Demand output signal for axis 0
2 AGND
Analog ground
3 Shield
Shield connection
4 Demand1
Demand output signal for axis 1
5 AGND
Analog ground
6 Shield
Shield connection
7 Demand2
Demand output signal for axis 2
8 AGND
Analog ground
9 Shield
Shield connection
10 Demand
Demand output signal for axis 3
11 AGND
Analog ground
12 Shield
Shield connection
Description
Four independent command outputs
Output range: ±10VDC (±0.1%).
Resolution: 14-bit (accuracy ±1.22mV).
Output current: 1mA maximum
Update frequency: Immediate
MintMT and the Mint Motion Library use the analog outputs to control servo drives.
Demand / Command outputs 0 to 3 correspond to axes 0 to 3. The analog outputs may be
used to drive loads of 10k
Ω
or greater. The outputs are referenced to PC system ground.
Shielded twisted pair cable should be used. The shield connection should be made at one end
only.
NextMove PCI
Demand0
Demand
±100%
10k
10k
160k
-
+
AGND
Breakout
module
2
1
X7
100
pin
cable
Figure 2 - Analog output circuit - Demand0 shown
1
12
Summary of Contents for NextMove PCI
Page 1: ...NextMove PCI Motion Controller MOTION CONTROL Installation Manual 3 02 MN1903...
Page 2: ......
Page 6: ...iv Contents MN1903...
Page 16: ...3 4 Basic Installation MN1903...
Page 42: ...4 26 Input Output MN1903...
Page 57: ...Operation 5 15 MN1903 Figure 11 The NextMove PCI servo loop...
Page 74: ...5 32 Operation MN1903...
Page 90: ...A 8 Accessories MN1903...
Page 91: ......