www.baldormotion.com
Accessories A-7
MN1919
A.1.4 Regeneration resistors
Depending on the application, MicroFlex might require an external regeneration resistor to be
connected to pins R1 and R2 of connector X1. The regeneration resistor dissipates energy
during braking to prevent an over-voltage error occurring. See sections 3.6 and 3.7 for details
about choosing the correct resistor.
WARNING
: Electrical shock hazard. DC bus voltages may be present at these
terminals. Use a suitable heatsink (with fan if necessary) to cool the
regeneration resistor. The regeneration resistor and heatsink (if present)
can reach temperatures in excess of 80 °C (176 °F).
A
B
C
E
D
G
F
Baldor
catalog
Power
W
Res.
Ω
Dimensions
mm (inches)
catalog
number
W
Ω
A
B
C
D
E
F
G
RGJ139
100
39
165
(6.49)
41
(1.61)
22
(0.87)
152
(5.98)
12
(0.47)
10
(0.39)
4.3
(0.17)
RGJ160
100
60
165
(6.49)
41
(1.61)
22
(0.87)
152
(5.98)
12
(0.47)
10
(0.39)
4.3
(0.17)
RGJ260
200
60
165
(6.49)
60
(2.36)
30
(1.18)
146
(5.75)
17
(0.67)
13
(0.51)
5.3
(0.21)
RGJ360
300
60
215
(8.46)
60
(2.36)
30
(1.18)
196
(7.72)
17
(0.67)
13
(0.51)
5.3
(0.21)
Figure 50 - Regeneration resistor dimensions
Summary of Contents for MicroFlex
Page 1: ...MicroFlex Servo Control SERVO DRIVE Installation Manual 03 10 MN1919...
Page 2: ......
Page 12: ...www baldormotion com 1 6 General Information MN1919...
Page 16: ...www baldormotion com 2 4 Introduction MN1919...
Page 40: ...www baldormotion com 3 24 Basic Installation MN1919...
Page 70: ...www baldormotion com 5 18 Input Output MN1919...
Page 82: ...www baldormotion com 6 12 Configuration MN1919...
Page 94: ...www baldormotion com 8 8 Specifications MN1919...
Page 120: ...Index MN1919...
Page 122: ...Comments MN1919 Thank you for taking the time to help us...