www.baldormotion.com
5-10 Input / Output
MN1919
STEP0+
DGND
1
DS26LS31
STEP0-
3
NextMove ESB / controller
Step
Output
GND
MicroFlex / drive amplifier
DGND
Step
Connect shields at
one end only
6
Shield
‘X3’
‘X2’
10
11
DIR0+
DS26LS31
DIR0-
5
Dir
Output
Twisted pairs
Dir
9
Figure 33 - Stepper input - typical connection from a Baldor NextMove ESB
Note:
When using a NextMove ESB’s STEP and DIR outputs, do not connect the
STEP
x
- or DIR
x
- outputs to ground; leave them unconnected as shown in
Figure 33.
Incremental encoder
MicroFlex / drive amplifier
Step
Connect shields
at one end only
‘X3’
10
Twisted pairs
Dir
9
A+
A-
B+
B-
DGND
11
GND
5V
Encoder
supply
5V
Encoder
supply
GND
Figure 34 - Stepper input - typical connection from an incremental encoder
Note:
When using an incremental encoder source, do not connect the A- or B- outputs;
leave them unconnected as shown in Figure 34.
Summary of Contents for MicroFlex
Page 1: ...MicroFlex Servo Control SERVO DRIVE Installation Manual 03 10 MN1919...
Page 2: ......
Page 12: ...www baldormotion com 1 6 General Information MN1919...
Page 16: ...www baldormotion com 2 4 Introduction MN1919...
Page 40: ...www baldormotion com 3 24 Basic Installation MN1919...
Page 70: ...www baldormotion com 5 18 Input Output MN1919...
Page 82: ...www baldormotion com 6 12 Configuration MN1919...
Page 94: ...www baldormotion com 8 8 Specifications MN1919...
Page 120: ...Index MN1919...
Page 122: ...Comments MN1919 Thank you for taking the time to help us...
Page 123: ......