www.baldormotion.com
3-16 Basic Installation
MN1919
3.4.8 24V control circuit supply
A 24VDC supply must be provided to power the controlling electronics. This is useful for safety
reasons where AC power needs to be removed from the power stage but the controlling
electronics must remain powered to retain position and I/O information.
A separate fused 24V supply should be provided for the MicroFlex. If other devices are likely
to be powered from the same 24V supply, a filter (Baldor catalog number FI0014A00) should
be installed to isolate the MicroFlex from the rest of the system. Alternatively, a ferrite sleeve
may be attached to the supply cable near connector X2.
Location
Connector X2
Nominal input
voltage
24V
Range
20-30VDC
Input current
Maximum
Typical
1A continuous (4A typical power on surge, limited by NTC)
0.5A - 0.6A (no encoder power)
0.6A - 0.8A (if powering encoder)
Tightening torque for terminal block connections is 0.5-0.6Nm (4.4-5.3 lb-in).
Customer supplied
24VDC (fused)*
GND
24V filter
(optional)
+24V
STAR
POINT
Incoming safety
earth/ground (PE)
* Recommended fuse: Bussman S504 20x5mm anti-surge 2A
** Recommended ferrite sleeve: Fair-Rite part 0431164281 or similar
Use a twisted pair cable, with
ferrite sleeve attached close
to connector X2.
Ferrite
sleeve**
Figure 6 - 24V control circuit supply connections
Summary of Contents for MicroFlex
Page 1: ...MicroFlex Servo Control SERVO DRIVE Installation Manual 03 10 MN1919...
Page 2: ......
Page 12: ...www baldormotion com 1 6 General Information MN1919...
Page 16: ...www baldormotion com 2 4 Introduction MN1919...
Page 40: ...www baldormotion com 3 24 Basic Installation MN1919...
Page 70: ...www baldormotion com 5 18 Input Output MN1919...
Page 82: ...www baldormotion com 6 12 Configuration MN1919...
Page 94: ...www baldormotion com 8 8 Specifications MN1919...
Page 120: ...Index MN1919...
Page 122: ...Comments MN1919 Thank you for taking the time to help us...
Page 123: ......