www.baldormotion.com
3-8 Basic Installation
MN1919
3.2.6 Derating characteristic - 9A model
The following derating characteristics are for model FMH2A
09
TR-EN23.
0
1
2
3
4
5
6
7
8
9
30
35
40
45
50
55
Ambient temperature (°C)
Three-phase AC supply
Natural cooling
1m/s forced air
1.5m/s forced air
2.5m/s forced air
3.5m/s forced air
Notes:
Load power factor = 0.78.
Overload limit for model FMH2A09TR-EN23 is 18A.
R
at
ed
out
put
cur
rr
ent
(A
rm
s
)
Ambient temperature (°C)
Single-phase AC supply
R
at
ed
out
put
cur
rr
ent
(A
rm
s
)
0
1
2
3
4
5
6
7
8
9
30
35
40
45
50
55
Natural cooling
1m/s forced air
1.5m/s forced air
2.5m/s forced air
3.5m/s forced air
3.2.7 Overtemperature trips
The MicroFlex contains internal temperature sensors that will cause it to trip and disable if the
temperature exceeds 80°C on the 1A or 3A models, or 75°C on the 6A and 9A models. This
limit can be read using the
TEMPERATURELIMITFATAL
keyword - see the Mint help file for
details.
Summary of Contents for MicroFlex
Page 1: ...MicroFlex Servo Control SERVO DRIVE Installation Manual 03 10 MN1919...
Page 2: ......
Page 12: ...www baldormotion com 1 6 General Information MN1919...
Page 16: ...www baldormotion com 2 4 Introduction MN1919...
Page 40: ...www baldormotion com 3 24 Basic Installation MN1919...
Page 70: ...www baldormotion com 5 18 Input Output MN1919...
Page 82: ...www baldormotion com 6 12 Configuration MN1919...
Page 94: ...www baldormotion com 8 8 Specifications MN1919...
Page 120: ...Index MN1919...
Page 122: ...Comments MN1919 Thank you for taking the time to help us...
Page 123: ......