General Information 1-9
MN1269
Servo Control Card
Output
:
LD3015HS
Rated Bus Voltage (VDC nominal)
160
Rated Continuous Current (A)
15
Current Limit Adjust (A)
5-15
Peak Current Adjust (A) (maximum time 1.5 seconds)
30
Peak Current Adjust (A)
0-30
Switching Frequency (kHz)
20
Form Factor
1.01
Minimum Inductance (mH)
2.0
Frequency Response (kHz)
2.5
Input
:
LD3015HS
Signal Input
〈±
VDC) See note 2.
5 to 15
Drift (
m
V/
°
C)
10
Overall Gain (A/V min)
0-6000
Auxiliary input:s
LD3015HS
See note 3.
Impedance (k ohms)
20
Power Requirements:
LD3015HS
Logic +15VDC
(mA)
–15VDC
(mA)
180
55
Bus range (VDC)
148-176
General:
LD3015HS
Weight (lbs.)
1.4
Operating Temperature (
°
C)
0-50
Notes:
1.
RMS current limit is a built–in function that turns off or folds back the servo control if the continuous current is exceeded
for an extended period of time. The (EC) fault indicator identifies the condition.
2.
Input signal (S) can be differential or single ended while the auxiliary (A) and tachometer (T) signals are single ended
for all models.
3.
The Left Limit, Right Limit and external Reset auxiliary input signals are connected through normally open (NO)
contacts while the external status I/0 signal is provided through a bi–directional Interlock. The current sense signal
(DCS) is provided as an analog representation of current. For information on usage, refer to Section 2.
Servo Systems Co. • 115 Main Road • P.O. Box 97 • Montville, NJ, 07045-0097
(973) 335-1007 • Toll Free: (800) 922-1103 • Fax: (973) 335-1661
www.servosystems.com